background image

WIRING 

 
Personal Injury Hazard. 
Power supply can cause electrical shock.  

Disconnect power supply before beginning installation. 

 
 
All wiring must comply the applicable local codes, ordinances and regulations.  Make wiring connections according to 
dehumidifier instructions; otherwise see typical wiring diagram in Figure 2. 
 

 
 

Figure 2 - Diagram for 

Dehumidifier 

 
 
 
 
 
 
 
ADJUSTMENTS 
Humidity Control Adjustment 

To maintain optimum humidity control without causing condensation on cold surfaces such as windows, the 
homeowner must adjust the set point as the outdoor temperate changes. 
 
To reduce the relative humidity, reduce the set point approximately three percent relative humidity every 24 hours.  
To increase the relative humidity increase the set point approximately three percent relative humidity ever 24 hours. 
 

 
Set Point Adjustment 

Set the humidity set point according to the prevailing outdoor temperature.  See table below for recommended 
settings. 
 
 
 

Recommended Humidity Controller Settings 

Outdoor Temperature 

F C 

Recommended Humidity 

Controller Setting 

-20 -29 

15 

-10 -23 

20 

0 -18  25 

+10 -12 

30 

+20 -7 

35 

>+20 >-7 

40 

 

 
 
OPERATION AND CHECKOUT 

Place the system in operation and observe through at least one complete cycle to make certain that all components 
are functioning properly. 
 
 
 