background image

Dehumidistat Installation Instructions 

 
 

 
APPLICATION 

The dehumidistat (humidity controller) provides automatic low voltage control of the dehumidifier in central heating 
and air conditioning systems.  It has a SPST, snap-acting, dust-proof switch and is designed for wall or surface duct 
mounting. 
 

 
INSTALLATION 

When installing the product . . .  

1.

 

Read these instructions carefully.  Failure to follow them could damage the product or cause a hazardous 
condition. 

2.

 

Check the ratings given in the instructions and on the product to make sure the product is suitable for 
your application. 

3.

 

Installer must be trained, experienced service technician. 

4.

 

After installation is complete, check out product operation as provided in these instructions. 

 

Personal Injury Hazard. 
Power supply can cause electrical shock.  

Disconnect power supply before beginning installation. 

 

Location and Mounting 

The dehumidistat can be mounted at any convenient location in the living area or equipment room.   
NOTE:  The electrical connections are not shared with the thermostat.   
 

Wall Mounting 

IMPORTANT - 

Mount the control in an area with average room temperature and average relative humidity.   

1.

 

Mark the holes for the two mounting screws (included).  Then mark the hole for the low voltage 
wiring.   

2.

 

Drill the holes. 

3.

 

Run low voltage wiring to the location and pull about 6 inches (152 mm) of wire through the hole. 

4.

 

Plug the hole with nonflammable insulation to prevent drafts from affecting the control operation.   

5.

 

Remove the case from the base.   

6.

 

Position the base on the wall with the arrow up. 

7.

 

Use the two, one inch (25 mm) mounting screws to secure the base to the wall.   

IMPORTANT –

 Use 18- to 22-gauge wire for proper wiring. 

8.

 

Connect the low voltage wires to the leads. 

9.

 

Replace the case. 

 
Duct Mounting 

IMPORTANT – 

When mounting near an elbow area, locate the control six includes (152 mm) upstream from the elbow 

so the element is exposed to the normal airflow (Figure 1). 

 

1.

 

Locate the control at least 8 includes (203 mm) upstream from the dehumidifier in the return air duct.  
(See Figure 1). 

2.

 

Apply the duct template to the duct location. 

3.

 

Use the duct template to make the opening and mounting hole. 

4.

 

Remove the dehumidistat case from the base.   

5.

 

Position the foam gasket on the base. 

6.

 

Position the base on the duct with the arrow up. 

7.

 

Use the four, one-inch (25 mm) mounting screws to 
secure the base to the duct. 

8.

 

Connect the low voltage wire to the leads. 

9.

 

Replace the case. 

IMPORTANT – 

Use 18- to 22-gauge wire for proper wiring. 

 

 
 
 
 

Figure 1 - Selecting 

Duct Location for 

Control 

 

Отзывы: