Air Specialties Softaire SAS-80DC3 Скачать руководство пользователя страница 2

ASSEMBLY INSTRUCTIONS

OPERATION

PLAN THE INSTALLATION

1. Before installation, you need to know:

ST4.2*13mm

Screw A
Screw B

Hanger bar 

ST4.2*25mm
13 3/8 in. (340mm)

ROOF CAP*

(with built-in

damper)

ROUND

DUCT*

WALL CAP*

(with built-in

damper)

*

 Purchase

separately

POWER

CABLE*

INSULATION*

(Place around and

over Fan Housing.)

Seal gaps

around

Housing.

FAN

HOUSING

ROUND 

ELBOW(S) *

Seal duct

joints with

tape.

Keep duct

runs short

Hole A 

Hole B 

Hole A 

Hole B 

Channel 

When installing contractor packs, make sure to install any optional modules such 

as speed controls or humidity sensors with the fan housing to ensure wiring is 

completed properly. Module and grille plugs come packaged with the optional 

accessory and must be installed with the fan housing.

5 to 7 feet

Gesture area

sensor 90°

MOTION SENSOR OPERATION only for SAS-80DC3HM

Plug the motion sensing grille into the fan control module and when powered on, the fan 

will automatically start sensing motion.

Turn on the switch to activate sensor and continuous ventilation system. The fan will run 

continuously at the pre-set low speed. 

When motion is detected, the fan speed increases to high speed.

When the person exits the area, the fan remains working at high speed until the delay time 

has passed (20 minutes). 

After the time delay, the fan speed is reduced to the continuous ventilation rate.

Installation distance: 5 to 7 feet.

Sensing range is within the cone angle of 90°.

 

1. Do not use in a cooking area.                                               2. Two ways to connect ductwork to a factory-shipped unit.

To Turn Fan ON

Turn the switch 

I

 (according to the following “CONNECT ELECTRICAL WIRING” ) ON.

• Fan will run at the certified airflow rate if the switch 

II

 is ON.

• Fan will run at the user-adjustable airflow rate if the switch II is OFF.

To Use Fan Time Delay Airflow Rate Change

1. Turn the switch 

I

 ON.

2. Turn the switch 

II

 ON - fan will run at the certified airflow rate.

3. When the switch 

II

 is turned OFF, fan will continue to run at the certified airflow rate until the time delay has elapsed (for SAS-80DC3, the delay time 

is user-adjustable from 3-30mins; for SAS-80DC3H SAS-80DC3HM, the delay time is 20 mins), and then will automatically change to the user-adjust-

able airflow rate.

To Turn Fan OFF

Turn the switch 

I

 OFF

Only for  SAS-80DC3H  SAS-80DC3HM

Fan run continuously at a low speed (adjustable by low airflow knob) and automatically boost up to high speed when either of these conditions is 

detected: a) Humidity above a user-adjustable setpoint (30%-80% relative humidity). b) rapid increases in humidity. After delay timer (20 minutes) 

returns fan to the default low speed. Humidity sensor description accroding to “HUMIDITY SENSOR OPERATION” and “SENSITIVITY ADJUSTMENT”.

HUMIDITY SENSOR OPERATION (Only for SAS-80DC3H SAS-80DC3HM)

The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid increases in humidity or (b) humidity above a user-adjustable 

set-point (30%-80% relative humidity). Fan run continuously at a pre-set lower level (set by Low airflow knob) and automatically boost up to certified 

airflow  rate when environmental conditions change. If the fan continuously responds to changing environmental conditions, “H” (means “humidity”) 

adjustment may- be required.

SENSITIVITY ADJUSTMENT (Only for SAS-80DC3H SAS-80DC3HM)

The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness control, the “H” may need 

to be increased toward maximum. If the control is responding too often to changing environmental conditions, movement toward minimum, “H” may be 

required.

To adjust the “H”:

1. Disconnect power at service entrance.

2. Through the grille, locate the slot marked “H”.

3. Carefully rotate the “H” adjustment toward maximum or minimum.

4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on.

5. Repeat above steps if necessary.

When the temperature changes, humidity sensor values will have deviation.

2

Содержание Softaire SAS-80DC3

Страница 1: ...ing do not damage electrical wiring and other hidden utilities f Ducted fans must always be vented to the outdoors g Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circu...

Страница 2: ...rate 3 When the switch II is turned OFF fan will continue to run at the certified airflow rate until the time delay has elapsed for SAS 80DC3 the delay time is user adjustable from 3 30mins for SAS 8...

Страница 3: ...he bottom of stud Screw housing to stud through the hole A and hole B on the same side Screw the hanger bar onto the stud through its hole Screw hanger bar to housing with screw A The minimum installa...

Страница 4: ...Harness Assembly Blower Wheel Wiring plate Motor plate UNIT BLACK BLK SWITCH BOX SWITCH I POWER SUPPLY 120V AC GROUND GRD WHITE WHT FAN RECEPTACLE WIRE PANEL SWITCH I SWITCH II SWITCH II BROWN BRN FAN...

Страница 5: ...conduit doit pointer vers le haut N INSTALLEZ PAS CET APPAREIL DANS UN MUR 3 Pour viter des dommages au roulement du moteur et des pales bruyantes ou d s quilibr es vitez que la poussi re de pl tre o...

Страница 6: ...D HUMIDIT Seulement SAS 80DC3H SAS 80DC3HM Le ventilateur d tection d humidit utilise un capteur d humidit sophistiqu qui r pond a augmentation rapide de l humidit ou b l humidit au dessus du r glage...

Страница 7: ...e bo tier en place par les trous A et B du m me c t Vissez la barre de suspension sur la poutrelle travers son trou Vissez la barre de suspension au bo tier l aide de la vis A La distance minimale d i...

Страница 8: ...4 5 6 7 8 9 10 11 12 a d e f b c Bo tier Vis Vis Vis Vis Vis Vis 1 2 1 Bo te d alimentation 1 1 1 1 1 1 1 1 1 3 3 3 1 1 1 Kit de barres de suspension 1 2 3 4 a b f e d 8 9 10 11 12 6 7 c 5 Connecteur...