![Air Oasis iAdaptAir L Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/air-oasis/iadaptair-l/iadaptair-l_manual_2875414017.webp)
Release
lever
Connectors
14
3. Squeeze the release lever on the back of the lamp connector while pulling
connector apart.
2. Slightly rotate and move the UV Lamp forward to remove it from the clips.
UV Lamp Replacement
1. Remove the filter cartridge and dust guard. (See instructions on pages 10-
Ensure the iAdaptAir
®
is disconnected from its’ power source before
performing any maintenance. UV Lamp may be hot. Allow time for the lamp
to cool before removing it.
4. Reverse the steps from (3-4) to install the new UVC lamp.
WARNING
OPTICAL RADIATION EXPOSURE HAZARD
DO NOT ATTEMPT TO OPERATE UNIT WITHOUT
ALLUMINUM SHELL COVERING AHPCO CELL.
DO NOT ATTEMPT TO REPLACE AHPCO
CELL WITHOUT DISCONNECTING POWER.
PERMANENT EYE AND SKIN DAMAGE MAY RESULT.
Hg lamp contains mercury. Manage in accord with disposal laws. Find disposal
centers at www.earth911.org.
For optimal performance and maximum efficiency of your iAdaptAir
®
, ensure
all UV Lamps are replaced annually.