CAUTION

UV  lamp  may  be  hot  and  could 

cause serious burns if not handled 

properly.  Please wait until AHPCO 

Cell has cooled to room tempera

-

ture to remove from unit.

Step 3

Remove three (3) wing-nuts secur

-

ing the AHPCO Cell in place.  Then 

slide the AHPCO Cell up and out of 

the unit.

AHPCO™ Cell contains Hg (Mer

-

cury)  and  should  be  disposed  of 

according to disposal laws.  Find 

disposal centers at www.earth911.

org.

Step 4

Reverse steps 1-3 to set new AHPCO Cell in place. Be sure to place the 

exposed tip of the fiber optic cord between the first rings of the new AHPCO 

Cell and in close proximity to the UV lamp.  This will ensure the indicator 

light functions properly.

Replacement Date Reminder

The AHPCO™ Cell should be replaced every three years.

3 Years Date:

 

 

 

6 Years Date:

 

 

 

9 Years Date:

 

 

 

Hg lamp contains mercury. Manage in accord with disposal laws. 

Find disposal centers at www.earth911.org.

WARNING:

 UV Light Hazard. Harmful to skin and eyes. Can cause 

temporary or permanent loss of vision. Never look at the lamp while 

illuminated. To prevent exposure to ultraviolet light, be sure the pow

-

er is disconnected before servicing.

WARNING: 

RISK  OF  ELECTRICAL  SHOCK.  CAN  CAUSE  INJU

-

RY OR DEATH: UNPLUG OR DISCONNECT UNIT FROM POWER 

SUPPLY BEFORE SERVICING.

Important Safety Instructions

When operating electrical appliances, basic precautions should always be fol

-

lowed.

WARNING 

To reduce the risk of fire, electric shock or injury:

• Do not use outdoors or on wet surfaces.

• Use only as described in this manual.

• Do not use with damaged cord or plug. If appliance is not working as it should, 

has been dropped, damaged, left outdoors, or dropped into water, call customer 

service at 1-800-936-1764.

• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.

• Do not handle plug or appliance with wet hands.

• Do not put  any object into openings.

• Turn off all controls before unplugging.

CAUTION

AHPCO™  Cell  contains  Hg  (Mercury)  and  should  be  disposed  of  according  to 

disposal laws.  Find disposal centers at www.earth911.org.

If the UV lamp is broken do not touch the cell or glass with your hands.

UV lamp may be hot and could cause serious burns if not handled properly. Please 

wait until the AHPCO Cell has cooled to room temperature to remove from unit.