Air Monitoring Solutions AMSP1001 Скачать руководство пользователя страница 5

Technical Manual 

AMSP1001 Personal Sampler 

 

 

AMSP1001 Personal Sampler Pump – Technical Manual 
Part Number: AMSP1001, Revisions Date June 2015; Issue 2 

Return to Contents

                                                                                  

Page 2 

 

Charger 

 
Ensure the charger power supply has adequate ventilation. 
 
 

Indoor Use Only  

 
The battery charger is intended for indoor use only do not use outdoors.  
 
 

Do Not Use a Damaged Battery Charger 

 
Never operate a damaged battery charger (doing so shall void warranty and may result in injury or damage). 
 
 

Battery Safety Warnings  

 

Avoid Short Circuits 

 
Avoid accidental short circuiting of any battery. Short circuiting battery terminals could an explosion, fire, burns 
and serious injuries. 
 

Do Not Use Damaged Battery Packs  

 
Never attempt to charge a visibly damaged battery pack or one that has odours emitting from it. 
This product contains a li-ion battery which may be dangerous if damaged. Contact AMS for inspection.  
 

Disposal  

 
Always  dispose  of  used  batteries  in  accordance  to  local  regulations  or  alternatively  contact  AMS  for  further 
advice. 
Do not disassemble. Do not throw the battery into fire or heat. The battery may burst or generate toxic gasses if 
heated.  
 

Charging Frequency  

 
The  battery  should  be  charged  after  every  shift.  Do  not  store  a  li-ion  battery  for  a  prolonged  period  in  a 
discharged state (doing so shall void warranty and will result in injury or damage). 
 
Do not leave pumps turned on for a prolonged period once the battery has gone flat. 
 

Contamination  

 
Whilst the pump typically operates with a high internal positive pressure, it should never be assumed that the 
pump  is  contamination  free.  Do  not  remove  covers  without  taking  suitable  precautions  to  prevent  escape  of 
contaminants. 
 
Any  products  to  be  returned  to  AMS  must  be  sent  in  a  sealed  labelled  bag  with  a  completed  certificate  of 
decontamination stating if and what types of hazardous materials the pump has been exposed to. 

Содержание AMSP1001

Страница 1: ...cal Manual AMSP1001 Personal Sampler AMSP1001 Personal Sampler Pump Technical Manual Part Number AMSP1001 Revisions Date June 2015 Issue 2 Air Monitoring Solutions AMS Personal Sampling Pump Technical Manual ...

Страница 2: ...solutions product is warranted against defects in materials and workmanship for a period of one year from the date of shipment excluding certain components batteries telescopic masts external tubing and loose accessories supplied with the 16l static sampling pump During the warranty period AMS will at its discretion either repair or replace products which prove to be defective For warranty service...

Страница 3: ...une 2015 Issue 2 Contents Warnings and Precaution Page 1 Quick Start Guide Page 3 Introduction Page 3 Construction Page 3 Equipment and Parts Page 4 Operation Page 5 Charging Connecting Air Tubing Activating Deactivating Pump Battery Indicator Adjusting Flow Rate Appendices Technical Specifications Page 6 Troubleshooting Page 7 ...

Страница 4: ...formed by qualified and approved maintenance personnel only Do not replace components with the power cable or battery connected Under certain conditions dangerous voltages may exist To avoid injuries and damage to the instrument always disconnect power and discharge circuits before touching them Do Not Substitute Parts Or Modify Instrument Because of danger of introducing additional hazards do not...

Страница 5: ...e dangerous if damaged Contact AMS for inspection Disposal Always dispose of used batteries in accordance to local regulations or alternatively contact AMS for further advice Do not disassemble Do not throw the battery into fire or heat The battery may burst or generate toxic gasses if heated Charging Frequency The battery should be charged after every shift Do not store a li ion battery for a pro...

Страница 6: ...id It is protected to IP40 as standard However higher ratings are available with the use of optional gasket sets It is coated in Black Textured Polyester Powder Paint All screws and fixings are countersunk into the case This construction removes many of the sharp edges found on other similar samplers whilst saving weight and producing a very tough hard wearing sampler Internally the sampler uses a...

Страница 7: ... Sampler Pump Technical Manual Part Number AMSP1001 Revisions Date June 2015 Issue 2 Return to Contents Page 4 Equipment and Parts Low Battery LED Flow Adjustment Potentiometer On Off Switch Pump Run LED Push Fit 8mm Air Fittings Belt Clip Battery Charge Socket ...

Страница 8: ... Air Tubing The pump is designed with easy to use 8mm push fit connectors To fit the air tubing simply insert the tubing into the connector until it clicks in place To remove first push and hold the black plastic ring down then gently remove the air tubing Activating Deactivating Pump To turn the pump on observe which direction the arrow on the switch is pointing Align the key with the arrow and g...

Страница 9: ...ns Date June 2015 Issue 2 Return to Contents Page 6 Appendices Technical Specifications Dimensions Weight 0 465kg Flow Rate 0 6 5 0 L min adjustable Flow Stability 3 Battery Li Po 2 cell 7 4v 1200mAh Approximate Run Time 8 hrs Environmental Requirements Ambient Temperature 5C 40C operating 5C 40C storage Humidity 25 75 ...

Страница 10: ...g the flow adjuster clockwise 2 Return the pump to AMS for inspection and repair Motor can be heard running but low or no airflow 1 Tubing not inserted fully 2 Blocked filter or air tubing 3 Internal fault 1 Check air fittings are fully inserted 2 Check for any obvious restrictions to the airflow 3 Return the pump to AMS for inspection and repair Battery fails to charge 1 Poor connection to charge...

Страница 11: ...Copyright 2015 ...

Отзывы: