Technical Manual
AMSP1001 Personal Sampler
AMSP1001 Personal Sampler Pump – Technical Manual Part Number: AMSP1001, Revisions Date June 2015; Issue 2
Air Monitoring Solutions AMS Personal Sampling Pump Technical Manual
Страница 1: ...cal Manual AMSP1001 Personal Sampler AMSP1001 Personal Sampler Pump Technical Manual Part Number AMSP1001 Revisions Date June 2015 Issue 2 Air Monitoring Solutions AMS Personal Sampling Pump Technical Manual ...
Страница 2: ...solutions product is warranted against defects in materials and workmanship for a period of one year from the date of shipment excluding certain components batteries telescopic masts external tubing and loose accessories supplied with the 16l static sampling pump During the warranty period AMS will at its discretion either repair or replace products which prove to be defective For warranty service...
Страница 3: ...une 2015 Issue 2 Contents Warnings and Precaution Page 1 Quick Start Guide Page 3 Introduction Page 3 Construction Page 3 Equipment and Parts Page 4 Operation Page 5 Charging Connecting Air Tubing Activating Deactivating Pump Battery Indicator Adjusting Flow Rate Appendices Technical Specifications Page 6 Troubleshooting Page 7 ...
Страница 4: ...formed by qualified and approved maintenance personnel only Do not replace components with the power cable or battery connected Under certain conditions dangerous voltages may exist To avoid injuries and damage to the instrument always disconnect power and discharge circuits before touching them Do Not Substitute Parts Or Modify Instrument Because of danger of introducing additional hazards do not...
Страница 5: ...e dangerous if damaged Contact AMS for inspection Disposal Always dispose of used batteries in accordance to local regulations or alternatively contact AMS for further advice Do not disassemble Do not throw the battery into fire or heat The battery may burst or generate toxic gasses if heated Charging Frequency The battery should be charged after every shift Do not store a li ion battery for a pro...
Страница 6: ...id It is protected to IP40 as standard However higher ratings are available with the use of optional gasket sets It is coated in Black Textured Polyester Powder Paint All screws and fixings are countersunk into the case This construction removes many of the sharp edges found on other similar samplers whilst saving weight and producing a very tough hard wearing sampler Internally the sampler uses a...
Страница 7: ... Sampler Pump Technical Manual Part Number AMSP1001 Revisions Date June 2015 Issue 2 Return to Contents Page 4 Equipment and Parts Low Battery LED Flow Adjustment Potentiometer On Off Switch Pump Run LED Push Fit 8mm Air Fittings Belt Clip Battery Charge Socket ...
Страница 8: ... Air Tubing The pump is designed with easy to use 8mm push fit connectors To fit the air tubing simply insert the tubing into the connector until it clicks in place To remove first push and hold the black plastic ring down then gently remove the air tubing Activating Deactivating Pump To turn the pump on observe which direction the arrow on the switch is pointing Align the key with the arrow and g...
Страница 9: ...ns Date June 2015 Issue 2 Return to Contents Page 6 Appendices Technical Specifications Dimensions Weight 0 465kg Flow Rate 0 6 5 0 L min adjustable Flow Stability 3 Battery Li Po 2 cell 7 4v 1200mAh Approximate Run Time 8 hrs Environmental Requirements Ambient Temperature 5C 40C operating 5C 40C storage Humidity 25 75 ...
Страница 10: ...g the flow adjuster clockwise 2 Return the pump to AMS for inspection and repair Motor can be heard running but low or no airflow 1 Tubing not inserted fully 2 Blocked filter or air tubing 3 Internal fault 1 Check air fittings are fully inserted 2 Check for any obvious restrictions to the airflow 3 Return the pump to AMS for inspection and repair Battery fails to charge 1 Poor connection to charge...
Страница 11: ...Copyright 2015 ...