1. Overview
AirLive SI-101 User Manual
6
1.5 Over The Air (OTA) Firmware Update
The device supports the Z-Wave firmware update via OTA.
Before starting the procedure, please remove the front cover of the device. Otherwise the
hardware check will be failed.
Let the controller into the firmware update mode, and then press the front tamper key once
to start the update.
After finish the firmware download, the LED will start flash in every 0.5 second. At that time,
please don't remove the battery
, otherwise it will cause the firmware broken, and the
device will no function.
After the LED stops flash, it is recommended that the user power up the device.
Caution:
After remove the battery, please wait about 30 seconds, and then re-install the
battery.
1.6 Security Network
The device supports the security function. When the device included with a security
controller, the device will auto switch to the security mode. In the security mode, the follow
commands need using Security CC wrapped to communicate, otherwise it will not
response.
COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2
1.7 Function DIP Switch
There is one function DIP switch in front of the device.
Remove the front co
ver in the right top of the PCB, and also has mark “M1” and “M2” for
two switch.
Notice
: SI-101 don't have DIP switch in hardware.
M1
M2
Description
ON
ON
Test Mode.
ON
OFF
Normal Mode.
OFF
ON
Normal Mode.
OFF
OFF
Customer Mode. According to the configuration setting NO.5 to set the
operation mode.