Air Live POE-FSH2422G-390 Скачать руководство пользователя страница 1

 

1

 

POE-FSH2422G-390

 

24-Port Full Power 802.3af PoE 
Web Smart Switch 

User’s Manual 

Содержание POE-FSH2422G-390

Страница 1: ...1 POE FSH2422G 390 24 Port Full Power 802 3af PoE Web Smart Switch User s Manual ...

Страница 2: ...hanical photocopying or recording without the written consent of OvisLink Corp OvisLink Corp has made the best effort to ensure the accuracy of the information in this user s guide However we are not liable for the inaccuracies or errors in this guide Please use with caution All information is subject to change without notice All Trademarks are properties of their respective holders ...

Страница 3: ...ease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device ...

Страница 4: ...Desktop Installation 10 2 6 Cabling Requirements 11 2 7 Connecting to Power 12 2 8 Reset to Default 12 3 LED Indicators 14 3 1 Comprehensive LEDs 14 3 2 LED Table 14 4 Web Management 15 4 1 Setup your computer for Web management 15 4 2 Remote Management 17 4 3 Get into the Web Management 19 4 4 Administrator 20 4 5 Authentication Configuration Administrator menu 21 4 6 System IP Configuration Admi...

Страница 5: ...er VLAN Setting 31 4 20 Multi to 1 Setting VLAN Setting 33 4 21 Per Port Counter 33 4 22 Trunking 34 4 23 QoS Setting 35 4 24 Priority Mode QoS Setting 35 4 25 Port 802 1p IP DS based QoS Setting 36 4 26 TCP UDP Port Based QoS Setting 36 4 27 Security 37 4 28 MAC Address Binding Security 37 4 29 TCP UDP Filter Security 38 4 30 Spanning Tree 39 4 31 STP Bridge Settings Spanning Tree 39 4 32 STP Por...

Страница 6: ...building wireless IP surveillance and VoIP networks It also provides port based and 802 1Q tag VLAN function to provide better traffic management reduces latency improve security and save bandwidth This is also a cost saving feature as it reduces the need to add additional hardware to the network These 24 10 100Mbps RJ 45 support the IEEE 802 3af PoE protocol Each port and transmit a maximum power...

Страница 7: ... For detailed installation instruction please see chapter 2 for more information Power On the switch The POE FSH2422G 390 Switch has a built in power supply to operate with 100 240V AC 50 60Hz power source The AC power cord connector is located at the rear of the unit and the On Off switch is next to the connector After the Switch is powered on it will perform self diagnostic test This process tak...

Страница 8: ...Flashing Data activating 26 1 26 On Port is linked to Power Device 24 1 24 PoE Off No Power Device is connected 24 1 24 1 4 Installation Steps This section lists the installation procedures in steps Each step s instruction is thoroughly explained in the subsequent sections of this chapter Step 1 Connect your device s PoE port to the switch s POE port see Figure A The Gigabit ports are not PoE port...

Страница 9: ...nt to install the switch on the 19 rack please install the mounting kit according to Figure C Step 4 Your PoE device should get the power from the switch now If you want to change settings via web management Please follow the instructions below Step 5 Set your PC s IP address to 192 168 2 50 Step 6 Open your web browser and enter 192 168 2 1 to get into the switch s web management ...

Страница 10: ...E FSH 2422G 250 POE FSH2422G 390 Power Consumption 250 Watts Max 390 Watts Max Power Input 100 240V AC 50 60Hz Max supply PoE Power per Device 15 4Watts per Port 250 Watts totally 15 4Watts per Port Full Power Dimensions 445 220 45 mm L x W x H 440 332 44 mm L x W x H Weight 2 54 kg 4 7 kg Operating Temperature 0 to 45 Storage Temperature 20 to 90 Humidity 10 to 90 RH non condensing Certifications...

Страница 11: ...package Follow the steps below to unpack your package contents Clear out an adequate space to unpack the package carton Open the package carton and take out the contents carefully Put back all the shipping materials such as plastic bag padding and linings into the package carton and save them for future transport need After unpacking and taking out the entire package contents you should check whet...

Страница 12: ... automatically activated when a compatible terminal is identified and the PoE port will supply power to the connected PoE device For legacy devices that are not yet compatible the PoE port will not offer the power to these devices This feature allows users to freely and safely mix legacy and Power over Ethernet compatible devices on their network These ports support network speeds of either 10Mbps...

Страница 13: ...al 1000BASE SX LX mini GBIC module The 1000BASE T port 25 and 26 are the same ports with the mini GBIC port 25 and 26 when plug in the mini GBIC module the device will activate mini GBIC and the RJ45 port will be disabled Reset The Reset button is to reset all the setting back to the factory default Note Be sure that you recorded the setting of your device else all the setting will be erased when ...

Страница 14: ...100 meters Adequate space should be allowed in front of all the ports so that each port is easily accessible for cable connections Leave at least 10cm 4 inch of space around the switch to allow heating dissipation 2 4 Rack Mounting The POE FSH2422G 390 PoE Switch can be mounted on a standard size 19 inch rack which can in turn be placed in a wiring closet with other equipments Before you can mount...

Страница 15: ...ion The POE FSH2422G 390 PoE Switch has four rubber pads attached on each corner of its underside These pads serve as cushioning against vibration and prevent the switch from sliding off its position They also allow adequate ventilation space when you place the switch on top of another device ...

Страница 16: ...per module require Cat 5 twisted pair UTP STP cable for connection When configuring within the 10 100 1000BASE T cabling architecture the cable distance should be within 100m The following table summarizes the cable requirement for 10 100 1000BASE TX connection 10BASE T 100 ohm Category 3 4 5 UTP STP cable 100BASE TX 100 ohm Category 5 UTP STP cable 1000BASE T 100 ohm Category 5 UTP STP cable or b...

Страница 17: ...h its power connection simply plug the female end of the power cord into the power connector on the rear of the switch and the male end of the power cord into a suitable power outlet Once you have correctly plugged in the power you can then turn on the Power Switch to activate the switch 2 8 Reset to Default When you forgot your IP or password please use the reset button for the factory default se...

Страница 18: ...tion of the Switch AirLive POE FSH2422G 390 User s Manual 13 Key in the user ID and the password to pass the authentication the user ID and the password are admin IP Address 192 168 2 1 ID admin Password airlive ...

Страница 19: ...chapter and get familiar with the front panel LED indicators of your Switch 3 1 Comprehensive LEDs 3 2 LED Table LED Status Description No of LED Power On Power on Power On Link 1000Mbps 1000M off Link 10 100Mbps 2 25 26 On Link 26 1 26 Link ACT Flashing Data activating 26 1 26 On Port is linked to Power Device 24 1 24 PoE Off No Power Device is connected 24 1 24 3 3 LED Indicators ...

Страница 20: ...et your computer to the same subnet as the switch For two network devices to be on the same subnet they must have the following 2 criteria Their IP address must be on the same subnet For example if one IP address is 192 168 0 1 The other s IP address must be 192 168 0 x x is any number between 2 and 254 for Class C subnet To find out the IP address information for your computer Under WinNT 2000 XP...

Страница 21: ...ge the computer s IP Step 1 Double click on the network connection status icon on the task bar This should bring up a window showing the status of the current network connection If there is no network status icon on the task bar please go to the Start Settings Network Local Connection of the task bar s Start menu Step 2 Clock on the property icon Step 3 Double click on the Internet Protocol TCP IP...

Страница 22: ... ability This allows DHCP server or router to assign IP automatically However we do not recommend turning on the DHCP client because the DHCP server assign the IP randomly The DHCP client should be used only when connecting directly to Cable Modem for remote management whose service provider uses DHCP for IP assignment Now you will be able to access the switch by typing in the switch s IP address ...

Страница 23: ...r the IP address Subnet Mask and Gateway information offered by your ISP If your ADSL connection is PPPoE or PPTP type you have to connect through a router for remote management Cable Modem If your Cable service provider uses DHCP for IP assignment please turn on the DHCP function under IP configuration Make sure there is no DHCP server in the network Then the Cable provider will assign the switch...

Страница 24: ... s LAN port address 192 168 0 254 Please make sure the subnet mask is the same as the router s On the Router Go to router s Virtual Server setting and open the Web port TCP Port 80 to the switch s IP address 192 168 0 200 If your router require enter the beginning and ending Port from PortX to PortX enter 80 for both Now the Remote PC will be able to access your switch by entering 201 100 1 5 in t...

Страница 25: ... switch s image on the upper portion of the screen gives the quick overview of the port connection status When a port is plugged in the switch s image will show a plug on the corresponding port Click on a port will show the quick port status 4 4 Administrator There are many management functions can be set or performed if you click the Administrator on Home Page including Authentication Configurati...

Страница 26: ...iguration Administrator menu This page shows authentication configuration information User can set new Username and Password in this page 4 6 System IP Configuration Administrator menu This page shows system configuration including the current IP address and sub net mask and gateway ...

Страница 27: ...e successfully then press Reboot button It will enter user login screen automatically 4 7 System Status Administrator menu This page is used to check the status of switch including Switch MAC address and software version The comment field allows the network administrator to input an easy to remember nickname for this switch The legal characters are a z and A Z _ 0 9 excluding special character MAC...

Страница 28: ...the default value Step 1 To activate this function the user should follow the following procedures Press the Load default button for 3 seconds until you see the LED blinking Step 2 When LED starts blinking it means the CPU is executing the load default procedure You can release the button now After completing this procedure all the factory default value will be restored It includes the IP address ...

Страница 29: ...ator menu Click Confirm button to reboot the device Note The reboot is for software base instead of hardware base 4 11 Port Management There are many management functions can be set or performed if you click the Port Management on Home Page including Port Configuration Port Mirroring Bandwidth Control Broadcast Storm Control POE In the following sessions we will talk in detail about the management...

Страница 30: ... as Enable the Speed Duplex mode Pause Backpressure TX Capability and Address Learning are negotiated automatically When you set it as Disable you have to assign those items manually Speed When the Auto Negotiation column is set as Disable users have to set the connection speed to the ports ticked Duplex When the Auto Negotiation column is set as Disable users have to set the connection mode in Ha...

Страница 31: ...pdate to have the configuration take effect Current Status Displays current port status Setting Status Displays current status Click Update to make the configuration effective 4 13 Port Mirroring Port Management menu The Port mirroring is a method for monitoring traffic in switched networks That Traffic through ports can be monitored by any of the ports means traffic goes in or out monitored sourc...

Страница 32: ... ports by ticking the check boxes beneath the port number label to be monitored And then click Update to have the configuration take effect 4 14 Bandwidth Control Port Management menu This page allows the setting of the bandwidth for each port The TX rate and RX rate can be filled with the number ranging from 1 to 255 This number should be multiplied by the selected bandwidth resolution to get the...

Страница 33: ...elected port and the number of broadcast packets is counted in every time unit One time unit is 500 us for 10Mbps speed and 5ms for 100Mbps The excessive broadcast packet will be discarded For those broadcast packets incoming from the un selected port the switch treats it as the normal traffic Threshold Type in the threshold in the range between 1 and 63 to limit the maximum byte counts which a po...

Страница 34: ...bers of the same VLAN will receive traffic from the ones of the same VLAN Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physically There are many management functions can be set or performed if you click the VLAN Setting on Home Page includin...

Страница 35: ...tant since here the handover between the switches of your network takes place VLAN Mode Displays VLAN mode port based Tag based VLAN Here you can also switch back to Port Based VLAN Mode Add tag means the outgoing packet of the selected port will be inserted a 802 1Q tag Use this setting for your Up and Downlink Ports in your VLAN Tagged Network Don t care means the outgoing packet of the selected...

Страница 36: ...s Manual 31 4 19 VLAN Member VLAN Setting The ports need to be made member of your VLAN groups This is for Tag Based and Port Based VLAN Mode The screen here looks different whether you run Tag Based or Port Based Mode VLAN Member in Port Based Mode ...

Страница 37: ... Only the numbers are important There firstly add your VLAN Groups identified throughout your network by unique and constant numbers Start with IDs from 100 and up Keep in mind that some switches use 1 as the default while others use 4095 or 4096 as default Starting with 100 gives you enough free room and less compatibility issues So enter 100 in the field right of VID Setting then select or desel...

Страница 38: ... Per Port Counter This page provides port counter of each port There are 4 categories Receive Packet Transmit Packet Transmit Collision Receive Packet Drop Receive CRC error Once you change the counter category the counter will be cleared automatically Transmit packet collision This category shows the packets outgoing from the switch and the count of collision Receive packet Transmit packet This c...

Страница 39: ... hash algorithm automatically applies load balancing to the ports in the trunk A port failure within the trunk group causes the network traffic to be directed to the remaining ports Load balancing is maintained whenever a link in a trunk is lost or returned to service This switch may use Port ID Source MAC Address Destination MAC Address or a combination of Source MAC Address and Destination MAC A...

Страница 40: ...ates high priority traffic from lower priority traffic Tags may be added to the packets to identify such classes but they do not guarantee delivery as do quality of service QoS functions which are implemented in the network devices There are many management functions can be set or performed if you click the QoS Setting on Home Page including Priority Mode Port 802 1p IP DS based TCP UDP Port Based...

Страница 41: ...forwarded according to the number set in each queue 4 25 Port 802 1p IP DS based QoS Setting 4 26 TCP UDP Port Based QoS Setting The user can select the protocol that will be forwarded as the specified mode There are 3 user defined UDP TCP port groups and many well known TCP UDP ports The user defined port number may be a range or a specific number depending on the mask The operating theory for al...

Страница 42: ...ng Security This function provides a method for the administrator to specify the relationship between the physical port and the MAC address Only the packet with specified source MAC address can be forwarded By specifying the MAC address to each port the network administrator can prevent the unauthorized user from accessing the switch Each port can correspond to up to 3 MAC addresses To activate th...

Страница 43: ...le the binding function Click Update to have the configuration take effect Note Setting the multicast address to these fields is not allowed A warning message will show up if you do so 4 29 TCP UDP Filter Security By selecting the TCP UDP port the network administrator can optionally block some specific applications There are two kinds of protocol filter functions The forward function makes the sw...

Страница 44: ...panning Tree menu 4 31 STP Bridge Settings Spanning Tree Bridge Priority This parameter configures the spanning tree priority globally for this switch The device with the highest priority becomes the STP root device However if all devices have the same priority the device with the lowest MAC address will then become the root device Number between 0 61440 in increments of 4096 Therefore there are 1...

Страница 45: ...uration message before attempting to reconfigure That also means the maximum life time for a BPDU frame Number between 6 40 default is 20 Forward Delay The maximum time in seconds the root device will wait before changing states i e discarding to learning to forwarding Number between 4 30 default is 15 4 32 STP Port Settings Spanning Tree ...

Страница 46: ... the best path between devices Therefore lower values should be assigned to ports attached to faster media and higher values assigned to ports with slower media Set the RSTP path cost on the port Number between 0 200000000 0 means auto generated path cost State Show the current port state includes designated port root port or blocked port Status Show the current port status includes forwarding dis...

Страница 47: ...vides the user with a method to backup recovery the switch configuration The user can save configuration file to a specified file If the user wants to recover the original configuration which is saved at the specified path just enter the password and then press the upload button Finally the original configuration of the switch will be recovered ...

Страница 48: ...4 Web Management AirLive POE FSH2422G 390 User s Manual 43 4 35 Miscellaneous Miscellaneous setting is used to configure output queue aging time VLAN stride and IGMP snooping ...

Страница 49: ...ter whether destination port is in the same VLAN IGMP Snooping When this function is enabled the switch will execute IGMP snooping version 1 and version 2 without the intervention of CPU The IGMP report and leave packets are automatically handled by the switch 4 36 SNMP Simple Network Management Protocol is a set of protocols for managing complex networks The SNMP network contains 3 key elements m...

Страница 50: ...FSH2422G 390 User s Manual 45 4 37 Logout The administrator has write access for all parameters governing the onboard agent User should therefore assign a new administrator password as soon as possible and store it in a safe place ...

Страница 51: ...ith RJ 45 Connectors 24 port with PoE 10 100 1000BaseT with RJ 45 Connectors 2 Combo SFP Open Slots 2 MAC Address 4K Buffer Memory 2 75Mb Transmission Method Store and Forward Filtering Forwarding Rates 1000Mbps port 1 488 000pps 100Mbps port 148 800pps 10Mbps port 14 880pps Transmission Media 10 100BaseTX Cat 5 UTP STP 1000BaseT Cat 5 Cat 5E UTP STP LED Indicators Per Port Link Act PoE Act Status...

Страница 52: ...E FSH2422G 390 User s Manual 47 Max supply PoE Power per Device 390Watts Dimensions 440 332 44 mm L x W x H Weight 4 7 kg Operating Temperature 0 to 45 Storage Temperature 20 to 90 Humidity 10 to 90 RH non condensing Certifications FCC Class A CE ...

Страница 53: ...the cabling type used is correct Check the corresponding Link Act FDX Col 100M for signs of faulty connection Check the status of the cable attachment If the problem persists try a different cable Try another port on the Switch Turn off power supply to the Switch After a while turn it on again to see if it resumes to its normal function If you find out where the problem is but cannot solve it by y...

Страница 54: ...dix B Troubleshooting AirLive POE FSH2422G 390 User s Manual 49 Key in the user ID and the password to pass the authentication the user ID and the password are admin IP 192 168 2 1 ID admin Password airlive ...

Отзывы: