7. Appendix
AirLive BU-3026/BU-3026-IVS User’s Manual
60
z
S
elect
Sensitivity
to set the detection sensitivity level. Higher sensitivity will make it
easier to detect and less objects missing, but more misjudgments.
z
Sel
ect
People / Vehicles / Anything
as the detected objects.
z
Select
Calibration (People
or
Vehicle Object Sizes)
.
The minimum and maximum
boundary of objects can be specified to improve the detection accuracy. The width
and length values must be at least 6 pixels. If any false detection caused by smaller
objects, you can try to increase the minimum size.
‐
Min. Size
of Calibration: The width and length values must be 6 pixels at least. If any
false detection caused by smaller objects, you can try to increase the minimum size.
‐
Max. Size
of Calibration: It has to be larger than the minimum size and half the frame
size is the most.
z
Set Event Action:
Go to the Event Schedule to Add or Edit the IVS event.
z
Up to4 zones can be specified when click the
Add Zone
function. Left click to add the
point and
15
points at most can be used in each zone.
z
Select
Delete Zone/All
to delete the zones.
z
Select
Enable/Disable
to allow the trigger or not.
z
Statistics Chart Display:
Here will show the detection result of e-Fence.