Air Liquide PRIMEJET Скачать руководство пользователя страница 5

3  Starting operation

 

 

The sequence must be strictly 

respected!

 

 

Explosion hazard! All parts such as tools 
and hands that come into contact with  
oxygen must be kept free from oil and 
grease.

3.1

   Before starting work, the instructions in 

this operating manual must be read and  
followed during the work!

3.2

   Check if the pressure regulator is suitable  

for the intended gas type and pressure 
(see symbol Point 3).

3.3

   Check if the cylinder valve connector and 

the seal are clean and undamaged. In 
case of any damage, the pressure regula-
tor must not be connected.

  

Before screwing on the pressure 

 

regulator, open the cylinder valve once 
briefly and close it again in order to blow 
out any possible dirt. Do not stand in 
front of the valve when doing this or hold 
your hand in front of the valve. (except 
for hydrogen and hydrogen mixtures, 
propane, corrosive, toxic and irritant 
gases, and flammable test gases). Ensure 
good ventilation.

3.4

   Connect the regulator with screw con-

nection to the bottle valve (1) using a 
suitable spanner or connection bracket 
(2) in a gas-tight manner. For regulators 
with manual connection (O-ring seal), this 
screw connection must be tightened by 
hand. No tools must be used for manual 
connection. The mounting position of the 
regulator must always be vertical in rela-
tion to the pressure gauges.

3.5

   Connect the hose to the hose connector 

on the outlet stud (7) and to the consum-
er device. Hoses and hose connections 
(hose nozzles) shall be used according to 
actual and related standard. Secure the 
hoses with suitable hose clips.

3.6

  Adjusting the pressure

Before releasing the gas into the system, check 
the following:
1. 

 Correct version of the cylinder pressure 
regulator

2. 

 All indicators at zero

3. 

 Pressure fully turned off on the pressure  
adjustment screw (5) (anticlockwise)

4. 

 Re-adjustment valves are closed.

Then close the shut-off valve (6) and release 
pressure and pressure regulator by unscrewing 
the pressure adjustment screw (5). Open the  
cylinder valve slowly, the high-pressure gauge 
(3) indicates the cylinder pressure. Open the 
shut-off valve (6) and slightly open the corre-
sponding shut-off valve of the consumer device.  
Then screw down the pressure adjustment 
screw (5) to set the desired outlet pressure 
(operating pressure) and check it on the low 
pressure gauge (4). Correct the pressure set-
ting if the pressure dips. 

  

Carry out leak test with Air Liquide leak 
detection spray!

4  Stopping operation

• 

 For short shutdown periods: close the  
shut-off valve on the pressure regulator.

•  

 For longer shutdown periods: Close the  
cylinder valve, release pressure, pres-
sure regulator has zero pressure, loosen 
pressure adjustment screw (5). Close the 
shut-off valves on the pressure regulator 
and the consumer device. Never tighten 
or loosen screw connectors while they 
are under pressure!

Отзывы: