are ready to use medical oxygen cylinders complete with  

an integrated regulator-valve and flow meter which are intended to supply regulated medical 
oxygen to a patient or another medical device. They deliver medical oxygen either through a 
flow regulated barbed outlet or a fixed flow sleeved outlet.

 Presence

TM

 Presence

TM  

Presence

TM

 

 PRE

 

PR PRC 

 

Key features:

3

  Easy to use and ergonomic for  

a quick and easy set-up

3

  Eliminates the cost of additional  

equipment (separate regulators  
and flowmeters)

3

  Unique interlocking feature to  

prevent accidental valve opening

3

  Dedicated carry handle* and  

bed/wall/trolley system  
minimising WHS issues

3

  Available in small sizes for  

ambulatory needs and large size  
for backup requirements

* Not available with the PRE

3

Содержание Presence PR

Страница 1: ...www airliquidehealthcare com au PresenceTM PR PRC PRE Instructions for Use...

Страница 2: ...ed by Air Liquide Medical Systems 6 rue Georges Besse 92182 Antony France and is supplied as part of the Presence range of products in Australia by Air Liquide Healthcare Pty Ltd 5 476 Gardeners Road...

Страница 3: ...outlet or a fixed flow sleeved outlet PresenceTM PresenceTM PresenceTM PRE PR PRC Key features 3 Easy to use and ergonomic for a quick and easy set up 3 Eliminates the cost of additional equipment sep...

Страница 4: ...arged and check that the pressure indicated on the gauge matches the pressure on the product label If the cylinder has already been used check the pressure gauge to ensure there is sufficient medical...

Страница 5: ...n is flowing from the barbed outlet before administering to patient e When therapy has concluded turn off the flow by turning the flow selector knob in an anti clockwise direction until it no longer m...

Страница 6: ...l f When required remove the attached equipment from the sleeved outlet and replace the cap g When attaching a suction unit to a PRE cylinder the use of a small extension piece will be required refer...

Страница 7: ...contact customer service and quarantine the unit for investigation by an Air Liquide Healthcare representative Check that the thread is not damaged to either the sleeved outlet or the device it s bei...

Страница 8: ...SA 95 Fullarton Road Kent Town SA 5067 Tel 08 8331 1648 eFax 02 9364 7477 VIC TAS 40 Bunnett Street North Sunshine VIC 3020 Tel 03 9300 5644 eFax 02 9364 7482 WA NT 51 Hampden Rd Nedlands 6009 Tel 08...

Отзывы: