2 – INSTALLATION
-8
NERTAMATIC 450 AC/DC
B) CONNECTION
The installation is wired for a 400V mains
voltage.
If the power supply voltage is 230V, 415V or 440V, the
transformers inside the power source must be rewired
accordingly.
Primary cable
P auxiliary wiring
CONNECTING NERTAMATIC 450
Remove the right side panel (10 mm key).
Wire the main transformer and the auxiliaries by means of terminal plates
PAB1, PAB2 and PAB3, depending on the local supply voltage. The unit is
supplied wired for 440V. DO NOT FORGET THE AUXILIARY WIRING
(PAB3).
Connect the power supply cable to the terminal plate (right-hand side of