![Air King SEVILLE SERIES Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/air-king/seville-series/seville-series_operation_2874891002.webp)
CAUTION:
MAKE SURE THE SURFACE YOU ARE MOUNTING THE
POWER UNIT TO IS CAPABLE OF SUPPORTING THE WEIGHT OF THE UNIT.
OTHERWISE YOU WILL NEED TO REINFORCE THE AREA.
SECTION 3
Ducting
CAUTION:
ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL
BUILDING CODES.
WARNING:
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
1.
Install the included duct collar to the hood with two of the provided 3 x 11
mm screws
(Figure 3)
.
2.
Connect the ducting to the duct collar and secure in place using tape to
seal all joints
(Figure 3)
.
NOTE:
The duct connector is 5.8" in diameter (for 6" round ducting) and the
center is located 3-3/16" inches from the back wall.
CAUTION:
ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A
WALL OR ROOF CAP.
SECTION 4
Wiring
CAUTION:
ALL ELECTRICAL CONNECTIONS MUST BE MADE IN
ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL
CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL
WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
1.
Attach the wire compartment to the power unit with two of the provided
3 x 11 mm screws. Remove the wire compartment cover and connect the
white wire (on some models this wire will be brown) from the power unit
to the white wire from the supply. Connect the black wire (on some models
this wire will be blue) from the power unit to the black wire of the supply.
Connect the ground wires from the home (green or bare) and the power
unit (green/yellow) to the grounding screw in the wire compartment. Use
approved methods for all connections
(Figure 4)
.
www.airkinglimited.com
000000000 Rev A. 5-08
INSTALLATION INSTRUCTIONS
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL
BEFORE STARTING INSTALLATION.
SECTION 1
Preparing the Range Hood
1.
Unpack hood from the carton and confirm that all pieces are present. In
addition to the range hood you should have:
1 - Package containing:
1 - duct collar
4 - 3 mm x 11 mm mounting screws
4 - 4 mm x 15 mm mounting screws
24 models: 2 - Aluminum Grease Filters (shipped installed)
30 models: 3 - Aluminum Grease Filters (shipped installed)
2 -50 watt Halogen lamps
1 - Instruction/Safety Sheet
NOTE:
Some hoods may be shipped with a protective plastic adhered to the
underside of the unit. It is recommended to leave this in place during installation
to protect it from scratching. Remove when the installation is complete.
SECTION 2
Installing the Range Hood
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL
BEFORE STARTING INSTALLATION.
CAUTION:
WHEN CUTTING OR DRILLING INTO WALL DO NOT DAMAGE
ELECTRICAL WIRING AND OTHER HIDDEN UTILITIES.
1.
Cut an appropriate size hole into the cabinet or canopy the power unit will
be mounted into
(Figure 1)
:
SEV24SS models:
18" wide by 10" deep.
SEV30SS models:
30" wide by 10" deep
NOTE:
If you will not have access to the ducting or wiring once the hood is installed
into the cabinet or canopy, make the ducting and electrical connections at this
point by referring to the
SECTION 3
and
SECTION 4
of this instruction sheet.
NOTE:
If an optional hood liner is being utilized, install at this point according
to the instructions included with the liner.
2.
Insert the power unit into the hole and secure in place using the four
provided 4 x 15 mm mounting screws
(Figure 2)
.
2 of 20
Figure 3
Ducting
Duct Collar
Power Unit
Figure 1
18" or 30"
10"
Figure 2