Air King SEVILLE SERIES Скачать руководство пользователя страница 2

CAUTION:

 

MAKE SURE THE SURFACE YOU ARE MOUNTING THE

POWER UNIT TO IS CAPABLE OF SUPPORTING THE WEIGHT OF THE UNIT.
OTHERWISE YOU WILL NEED TO REINFORCE THE AREA.

SECTION 3

Ducting

CAUTION:

 

ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL

BUILDING CODES.

WARNING:

 

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

1.

Install the included duct collar to the hood with two of the provided 3 x 11
mm screws 

(Figure 3)

.

2.

Connect the ducting to the duct collar and secure in place using tape to
seal all joints 

(Figure 3)

.

NOTE:

 The duct connector is 5.8" in diameter (for 6" round ducting) and the

center is located 3-3/16" inches from the back wall.

CAUTION:

 ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A

WALL OR ROOF CAP.

SECTION 4

Wiring

CAUTION:

 

ALL ELECTRICAL CONNECTIONS MUST BE MADE IN

ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL
CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL
WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

1.

Attach the wire compartment to the power unit with two of the provided
3 x 11 mm screws. Remove the wire compartment cover and connect the
white wire (on some models this wire will be brown) from the power unit
to the white wire from the supply. Connect the black wire (on some models
this wire will be blue) from the power unit to the black wire of the supply.
Connect the ground wires from the home (green or bare) and the power
unit (green/yellow) to the grounding screw in the wire compartment. Use
approved methods for all connections 

(Figure 4)

.

www.airkinglimited.com

000000000 Rev A. 5-08

INSTALLATION INSTRUCTIONS

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL

BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Range Hood

1.

Unpack hood from the carton and confirm that all pieces are present. In
addition to the range hood you should have:

1 - Package containing:

1 - duct collar
4 - 3 mm x 11 mm mounting screws
4 - 4 mm x 15 mm mounting screws

24 models: 2 - Aluminum Grease Filters (shipped installed)
30 models: 3 - Aluminum Grease Filters (shipped installed)
2 -50 watt Halogen lamps
1 - Instruction/Safety Sheet

NOTE:

 Some hoods may be shipped with a protective plastic adhered to the

underside of the unit. It is recommended to leave this in place during installation
to protect it from scratching. Remove when the installation is complete.

SECTION 2

Installing the Range Hood

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL

BEFORE STARTING INSTALLATION.

CAUTION:

 

WHEN CUTTING OR DRILLING INTO WALL DO NOT DAMAGE

ELECTRICAL WIRING AND OTHER HIDDEN UTILITIES.

1.

Cut an appropriate size hole into the cabinet or canopy the power unit will
be mounted into 

(Figure 1)

:

SEV24SS models:

 18" wide by 10" deep.

SEV30SS models:

 30" wide by 10" deep

NOTE:

 If you will not have access to the ducting or wiring once the hood is installed

into the cabinet or canopy, make the ducting and electrical connections at this
point by referring to the 

SECTION 3

 and 

SECTION 4

 of this instruction sheet.

NOTE:

 If an optional hood liner is being utilized, install at this point according

to the instructions included with the liner.

2.

Insert the power unit into the hole and secure in place using the four
provided 4 x 15 mm mounting screws 

(Figure 2)

.

2 of 20

Figure 3

Ducting

Duct Collar

Power Unit

Figure 1

18" or 30"

10"

Figure 2

Содержание SEVILLE SERIES

Страница 1: ... OR EXPLOSIVE MATERIALS AND VAPORS 6 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS CRAWL SPACES OR GARAGES 7 This unit must be grounded 8 To avoid motor bearing damage and no...

Страница 2: ...0000 Rev A 5 08 INSTALLATION INSTRUCTIONS CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION SECTION 1 Preparing the Range Hood 1 Unpack hood from the carton and confirm that all pieces are present In addition to the range hood you should have 1 Package containing 1 duct collar 4 3 mm x 11 mm mounting screws 4 4 mm x 15 mm mounting screws 24 models 2 Aluminum Gre...

Страница 3: ...lace and release handle The filter should snap securely into place Figure 6 NOTE If your model is equipped with a filter screw slide tab at rear of filter into slot in hood and secure filters in place by tightening screw located at front of filter DO NOT OVERTIGHTEN 3 If the grease filters become damaged replace with the Air King Model BCGF 01 Grease Filters Cleaning CAUTION DO NOT USE GASOLINE BE...

Страница 4: ...ons may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province FOR PARTS OR TECHNICAL ASSISTANCE Please call 1 800 465 7300 MONDAY THROUGH FRIDAY BETWEEN THE HOURS OF 8 AM AND 4 00 PM EST PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE Reference the type and style of product located on label inside of t...