![Air King ESDQ24 Series Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/air-king/esdq24-series/esdq24-series_operating-manual_2874808004.webp)
CAUTION:
ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A WALL OR
ROOF CAP.
SECTION 8
Finishing the Installation
1. Reinstall the filter by fitting into the channel of the hood and pushing upwards until it is
secured in place
(Figure 11).
2. Install the included 26 watt fluorescent lamp into the lamp holder by lining up the pins
on the lamp base to the socket of the lamp holder and gently turning clockwise until the
lamp snaps into place and is firmly seated in the lamp holder. Install a 4 watt maximum
type C7 (candelabra base) night light (not included) into the side lamp holder and reinstall
the lamp cover by squeezing the cover’s sides and fitting them into the slots on the hood.
3. Turn switches to the “OFF” position and restore power. Test that the light and the fan are
operating properly.
4. If there is any vibration noise, check for the source and try to tighten fasteners or adjust
the tape to make a tighter connection or seal.
SECTION 9
Controls
Your Range Hood is equipped with two rocker style switches with one controlling the lighting and
the other controlling the exhaust fan. The light switch has three positions, Main Light ( • ), Night
Light (
°
), and OFF. The fan switch has three positions, High ( • • ), Low ( • ), and OFF (
°
).
www.airkinglimited.com
5084459 Rev D. 11-12
4 of 12
SECTION 10
Maintenance
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE
SERVICING THE UNIT.
Filters
1.
Grease Filter
- Included with your range hood is an aluminum grease filter that should be
washed at least once a month. The filter is dishwasher safe and should be washed in a
mild soap or detergent. Reverse the instructions in the “Finishing the Installation” section
of the instructions to remove filters. If the grease filter become damaged, replace with Air
King Model GF-07 Grease Filter.
2.
Charcoal Odor Filter
- If you have installed the optional charcoal odor filter, it cannot
be washed and must be discarded and replaced when it becomes noticeably dirty, has
stopped filtering the odors, or at least once per year. Replace with Air King Model CF-07
Odor Filter.
Changing the Lamp
1. Remove the lamp cover by squeezing in the sides. The cover is held in place by tension
against the tabs on the hood.
Fluorescent Lamp:
Remove lamp by gently twisting counterclockwise to release the lamp
from the base. Installation is the reverse of removal. Replace with Air King model 26SBL or
a compatible 26W GU24 lamp.
Night Light:
Unscrew night light bulb from socket and replace with a 4 watt maximum type
C7 (candelabra base) night light bulb.
Fuse
1. To replace the fuse, turn the fuse cap located next to the wire connector counter clockwise
and pull out. Replace with only a 125-Volt fuse, 1-1/2 Amp Max. Reinstall the fuse back
into the hood
(Figure 7).
Cleaning
CAUTION:
DO NOT USE GASOLINE, BENZINE, THINNER, HARSH CLEANSERS, ETC.,
AS THEY MAY DAMAGE THE RANGE HOOD.
1. Clean your range hood with a mild detergent, such as dishwashing liquid, and dry with a soft
cloth.
NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS
. Completely dry before
restoring power.
NEVER IMMERSE ELECTRICAL PARTS IN WATER.
2. The fan assembly can be vacuumed when build up (dirt, lint, etc.) accumulates over time.
The fan is permanently lubricated and does not require oiling.
Troubleshooting Guide
Trouble
Probable Cause
Suggested Remedy
1. Hood does not operate when the switch is on.
1a. A fuse may be blown or a circuit tripped.
1a. Replace fuse or reset circuit breaker.
1b. Wiring is not connected properly.
1b. Turn off power to unit. Check that all wires are connected.
2. Hood is operating, but air moves slower than normal.
2.
Obstruction in the exhaust ducting.
2.
Check for any obstructions in the ducting including filter.
3. Hood is making a rattling noise.
3a. Filters are loose.
3a. Turn off power to unit. Check that all filter are securely in place.
3b. Duct connection is loose.
3b. Turn off power to unit. Check that duct connection is tight.
Installer:
Installation Date:
Place of Purchase:
Model Number:
Channel