Air King ESDQ24 Series Скачать руководство пользователя страница 4

CAUTION: 

ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A WALL OR 

ROOF CAP.

SECTION 8

Finishing the Installation

1.  Reinstall the filter by fitting into the channel of the hood and pushing upwards until it is 

secured in place 

(Figure 11).

2.  Install the included 26 watt fluorescent lamp into the lamp holder by lining up the pins 

on the lamp base to the socket of the lamp holder and gently turning clockwise until the 

lamp snaps into place and is firmly seated in the lamp holder. Install a 4 watt maximum 

type C7 (candelabra base) night light (not included) into the side lamp holder and reinstall 

the lamp cover by squeezing the cover’s sides and fitting them into the slots on the hood.

3.  Turn switches to the “OFF” position and restore power. Test that the light and the fan are 

operating properly.

4.  If there is any vibration noise, check for the source and try to tighten fasteners or adjust 

the tape to make a tighter connection or seal.

SECTION 9

Controls

Your Range Hood is equipped with two rocker style switches with one controlling the lighting and 

the other controlling the exhaust fan. The light switch has three positions, Main Light ( • ), Night 

Light (

°

), and OFF. The fan switch has three positions, High ( • • ), Low ( • ), and OFF (

°

).

www.airkinglimited.com

5084459 Rev D. 11-12

4 of 12

SECTION 10

Maintenance

CAUTION: 

MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE 

SERVICING THE UNIT.

Filters

1. 

Grease Filter

 - Included with your range hood is an aluminum grease filter that should be 

washed at least once a month. The filter is dishwasher safe and should be washed in a 

mild soap or detergent. Reverse the instructions in the “Finishing the Installation” section 

of the instructions to remove filters. If the grease filter become damaged, replace with Air 

King Model GF-07 Grease Filter.

2. 

Charcoal Odor Filter

 - If you have installed the optional charcoal odor filter, it cannot 

be washed and must be discarded and replaced when it becomes noticeably dirty, has 

stopped filtering the odors, or at least once per year. Replace with Air King Model CF-07 

Odor Filter.

Changing the Lamp

1.  Remove the lamp cover by squeezing in the sides. The cover is held in place by tension 

against the tabs on the hood.

 

Fluorescent Lamp:

 Remove lamp by gently twisting counterclockwise to release the lamp 

from the base. Installation is the reverse of removal. Replace with Air King model 26SBL or 

a compatible 26W GU24 lamp.

 

Night Light:

 Unscrew night light bulb from socket and replace with a 4 watt maximum type 

C7 (candelabra base) night light bulb.

Fuse

1.  To replace the fuse, turn the fuse cap located next to the wire connector counter clockwise 

and pull out. Replace with only a 125-Volt fuse, 1-1/2 Amp Max. Reinstall the fuse back 

into the hood 

(Figure 7).

  

Cleaning

CAUTION:

 DO NOT USE GASOLINE, BENZINE, THINNER, HARSH CLEANSERS, ETC., 

AS THEY MAY DAMAGE THE RANGE HOOD.

1.  Clean your range hood with a mild detergent, such as dishwashing liquid, and dry with a soft 

cloth. 

NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS

. Completely dry before 

restoring power. 

NEVER IMMERSE ELECTRICAL PARTS IN WATER.

2.  The fan assembly can be vacuumed when build up (dirt, lint, etc.) accumulates over time. 

The fan is permanently lubricated and does not require oiling.

Troubleshooting Guide

    Trouble 

 

Probable Cause 

 

Suggested Remedy

  1.  Hood does not operate when the switch is on. 

1a.  A fuse may be blown or a circuit tripped. 

1a.  Replace fuse or reset circuit breaker.

     

1b.  Wiring is not connected properly. 

1b.  Turn off power to unit. Check that all wires are connected.

  2.  Hood is operating, but air moves slower than normal. 

2. 

Obstruction in the exhaust ducting. 

2. 

Check for any obstructions in the ducting including filter.

  3.  Hood is making a rattling noise. 

3a.  Filters are loose. 

3a.  Turn off power to unit. Check that all filter are securely in place.

     

3b.  Duct connection is loose. 

3b.  Turn off power to unit. Check that duct connection is tight.

Installer: 

 

Installation Date: 

Place of Purchase: 

 

Model Number: 

Channel

Figure 11

Содержание ESDQ24 Series

Страница 1: ...ities CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS CRAWL SPACES OR GARAGES d Ducted fans must always be vented to the outdoors e This unit must be grounded f To avoid moto...

Страница 2: ...ood SECTION 3 Prepare the Hood for Installation 1 Choose the type of ducting you will require This model is equipped to vent either Vertically or Horizontally through a 3 1 4 x 10 duct It can be modified to be ductless re circulates the air back into the kitchen with the addition of a model CF 07 Charcoal Filter not included Figure 3 2a Horizontal or Vertical Remove the apprpriate square knockout ...

Страница 3: ... A QUALIFIED ELECTRICIAN 1 Connect the two loose White wires from the range hood to the White wire from the supply and the loose Black wire from the range hood to the Black wire of the supply Connect the ground wire green or bare from the supply to the green ground screw of the hood Use approved methods for all connections Figure 9 2 Install the wire compartment cover and tighten screw Make sure a...

Страница 4: ...and must be discarded and replaced when it becomes noticeably dirty has stopped filtering the odors or at least once per year Replace with Air King Model CF 07 Odor Filter Changing the Lamp 1 Remove the lamp cover by squeezing in the sides The cover is held in place by tension against the tabs on the hood Fluorescent Lamp Remove lamp by gently twisting counterclockwise to release the lamp from the...

Страница 5: ...CURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND A...

Страница 6: ...te 5S1429003 Black 5S1429006 6 1 GU24 Lamp Holder Assembly 5S1199703 7 1 Capacitor Harness 5S1111019 8 1 Blower Assembly 5S1144001 9 1 Wire Compartment Cover 5S1111048 10 1 Grease Filter GF 07 5S1144524 Charcoal Filter CF 07 5S1144624 11 1 Lamp Cover 5S1111053 12 1 Fuse 5S1111054 13 1 Fuse Holder 5S1199205 14 1 Lead Wire in Fuse Holder 5S1111055 15 1 Lead Wire Out Fuse Holder 5S1111056 16 1 26W GU...

Страница 7: ...NS LES MURS LES PLAFONDS OU LES GRENIERS LES GALERIES TECHNIQUES OU LES GARAGES AVERTISSEMENT POUR USAGE DE VENTILATION GÉNÉRALE EXCLUSIVEMENT NE PAS UTILISER POUR ÉVACUER DU MATÉRIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES d Les ventilateurs avec conduits doivent toujours être évacués vers l extérieur e Cette unité doit être mise à la terre f Pour éviter des dommages aux roulements des moteurs e...

Страница 8: ...en trou de serrure de la hotte SECTION 3 Préparez la hotte pour l installation 1 Déterminez le type de conduits dont vous aurez besoin Ce modèle peut évacuer l air verticalement ou horizontalement par un conduit de 8 25 cm sur 25 4 cm On peut également l utiliser sans évacuation il rejette alors l air dans la cuisine en ajoutant à filtre au charbon de modèle CF 07 non compris Figure 3 2a Évacuatio...

Страница 9: ...e au câble blanc de l alimentation et le câble noir lâche de la hotte au câble noir de l alimentation Branchez le fil de mise à la terre vert ou dénudé du bloc d alimentation à la vis de mise à la terre verte de la hotte Suivez les méthodes homologuées pour effectuer toutes les connexions Figure 9 2 Placez le couvercle du compartiment de fils et serrez la vis Assurez vous que tous les fils sont pl...

Страница 10: ...vez les jeter et vous en procurer des nouveaux Remplacez le par le filtre à odeur Air King de modèle CF 07 Changement de la lampe 1 Retirez l écran protecteur de lampe en appuyant sur les côtés Le panneau est maintenu en place grâce à la pression exercée sur les languettes de la hotte Ampoule fluorescente Retirez la lampe en tournant attentivement dans le sens contraire des aiguilles d une montre ...

Страница 11: ...E AUCUNE RESPONSABILITÉ EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA RÉPARATION DE TOUS FUSIBLES DISJONCTEURS OU RÉCEPTACLES DE MAISON MALGRÉ N IMPORTE QUOI À L EFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILITÉ D AIR KING SOUS UNE GARANTIE EXPRESSE OU TACITE NE DÉPASSERA LE PRIX D ACHAT DU PRODUIT ET UNE TELLE RESPONSABILITÉ SE...

Страница 12: ...e persienne Blanc 5S1429003 Noir 5S1429006 6 1 Assemblement de support de lampe GU24 5S1199703 7 1 Câble du condensateur 5S1111019 8 1 Assemblement de ventilateur 5S1144001 9 1 Couvercle du compartiment des fils 5S1111048 10 1 Filtre à graisses GF 07 5S1144524 Filtre à odeurs au charbon CF 07 5S1144624 11 1 Écran protecteur de lampe 5S1111053 12 1 Fusible 5S1111054 13 1 Socle à Fusible 5S1199205 1...

Отзывы: