Air King E130S Скачать руководство пользователя страница 12

   

 

 

# de pièce

  # 

Qté.  Description 

de remplacement 

  1 

Cabinet du ventilateur 

5S1202044 

  2 

Barre de montage 

5S1202045 

  3 

Écrou 

5S1202041 

  4 

Assemblée de collier en métal de 6 po 

5S5299100 

  5 

Vis 

5S1999010 

  6 

Joint – Collet 

5S1202054 

  7 

Joint - Extérieur 

5S1202053 

  8 

Cabinet de la Soufflante 

5S2202022 

  9 

Roue de la Soufflante 

5S2202023 

  10 

Écrou 

5S2202014 

  11 

Moteur 

5S2239001 

  12 

Plaque de Moteur 

5S2202020 

  13 

Vis de montage de moteur 

5S2202027 

  14 

Vis de la plaque de montage 

5S2202017 

  15 

Grille 

5S1202048 

  16 

Ressorts de la grille 

5S1202046 

  17 

Écrou de la bride 

5S1202031 

  18    2 

Passe-fil 

5S1202032 

  19    1 

Vis #10 de mise à la terre 

5S1999002 

  20    1 

Fil de mise à la terre de calibre # 14 

5S1999003 

www.airkinglimited.com

A210572218 New 7-09

12 of 12

DIAGRAMME DES PIÈCES DE REMPLACEMENT

       

 

# de pièce

  #    Qté.  Description 

de remplacement 

  21    1 

Assemblée du compartiment du fil - ES80S 

5S1239001 

  22    1 

Assemblée du compartiment du fil - ES130S 

5S1239002 

  A    1 

Compartiment du fil 

5S1239003 

  B    1 

Harnais du Capuchon - ES80S 

5S2239002 

      1 

Harnais du Capuchon - ES130S 

5S2239003 

  C    1 

Vis de montage du condensateur 

5S1202049 

  D    1 

Vis de la couverture du fil 

5S1202049 

  E    1 

Câble d’alimentation 

5S2239004 

  23    1 

Assemblée du compartiment du fil - ES80D 

5S1239004 

  24    1 

Assemblée du compartiment du fil - ES130D 

5S1239005 

  A    1 

Compartiment du fil 

5S1239006 

  B    1 

Vis #10 de mise à la terre 

5S1999002 

  C    1 

Câble de liaison ESD 

5S1239007 

  D    1 

SPDT relais de 120 volts 

5S1239008 

  E    2 

Vis de montage de relais 

5S1202049 

  F    1 

Vis de la couverture du fil 

5S1202049 

  G    1 

Câble

 

5S2239005 

  H    1 

Capot de câblages d’alimentation de 2 vitesses - ES80D 

5S2239006 

      1 

Capot de câblages d’alimentation de 2 vitesses - ES130D 

5S2239007 

  I    1 

Vis de montage du condensateur 

5S1202049 

1

2

3

4

3

2

5

16

15

17

18

8

9

10

11

12

13

14

6

25

19

20

21

22

23

24

ES80S

ES130S

ES80D

ES130D

C

B

A

D

E

B

A

C

D

E

F

G

H

I

Содержание E130S

Страница 1: ...ble codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back...

Страница 2: ...nails not included to the header Adjust the height of the housing so that it is flush with the finished ceiling by loosening the mounting bracket nuts and sliding the housing up or down on the bracket...

Страница 3: ...h speed Figure 9 www airkinglimited com A210572218 New 7 09 3 of 12 3b Intermittent Ventilation For two speed fans wired for intermittent ventilation with the recommended Air King model ESS2 switch no...

Страница 4: ...ng Refer to instructions in Section 5 Finishing the Installation to reinstall grill 2 Cleaning the Fan Assembly Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS...

Страница 5: ...PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMEN...

Страница 6: ...cription Replacement Part 21 1 Wire Compartment Assembly ES80S 5S1239001 22 1 Wire Compartment Assembly ES130S 5S1239002 A 1 Wire Compartment 5S1239003 B 1 Capacitor Harness ES80S 5S2239002 1 Capacito...

Страница 7: ...e aux incendies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refo...

Страница 8: ...hauteur du ch ssis pour qu il soit effleurement avec le plafond fini en desserrant les crous de support de montage et en glissant le ch ssis vers le haut ou vers le bas sur le support de montage Serre...

Страница 9: ...s ventilateurs deux vitesses c bl s pour la ventilation intermittente avec le commutateur ESS2 mod le recommand d Air King non inclus reliez le fil noir chaud de la source d nergie au 1C borne commune...

Страница 10: ...e l assemblage du ventilateur Nettoyer toutes les parties l aide d un chiffon sec ou passer d licatement l aspirateur sur le ventilateur NE JAMAIS IMMERGER LES PARTIES LECTRIQUES DANS L EAU Guide de d...

Страница 11: ...ER ET DANS AUCUN CAS AIR KING N ASSUME AUCUNE RESPONSABILIT EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUSI...

Страница 12: ...mplacement 21 1 Assembl e du compartiment du fil ES80S 5S1239001 22 1 Assembl e du compartiment du fil ES130S 5S1239002 A 1 Compartiment du fil 5S1239003 B 1 Harnais du Capuchon ES80S 5S2239002 1 Harn...

Отзывы: