INSTALLATION INSTRUCTIONS

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1. 

Unpack fan from the carton and confirm that all pieces are present. In addition to the 

exhaust fan you should have:

 

 

1 - Grill

 

 

1 - Damper Assembly (attached)

 

 

4 - Mounting Rails

 

 

1 - Mounting Flange

 

 

1 - Instruction/Safety Sheet   

2. 

Choose the location for your fan. To ensure the best air and sound performance, it is 

recommended that the length of ducting and the number of elbows be kept to a minimum, 

the radius of each elbow be as large as possible for the installation, and that insulated 

hard ducting be used. Larger duct sizes will reduce noise and airflow restrictions. This 

fan will require at least 10

 of clearance in the ceiling or wall, and will mount through 

drywall up to 3/4

 thick.

3. 

No additional vibration deadening materials are needed for this fan.

SECTION 2

New Construction

NOTE:

 If the mounting flange is installed on the fan housing, remove the two screws that 

connect the ceiling mounting flange to the housing and set aside 

(Figure 12).

1. 

Install the rails into the mounting channel on the housing. Center the mounting channel in 

the slots on the housing, then from inside the housing tighten the mounting channel nuts 

so the channel is securely in place. Position the housing next to the joist. Line up housing 

so that it will be flush with the finished ceiling. Secure the ends of the rails with screws or 

nails (not included) to the joists and slide the housing into the final position 

(Figure 1).

SECTION 3

Existing Construction

NOTE:

 If the mounting flange is installed on the fan housing, remove the two screws that 

connect the ceiling mounting flange to the housing and set aside 

(Figure 12).

1. 

Set housing in position between the joist and trace an outline onto the ceiling material 

(Figure 2).

 Set housing aside and cut opening, being careful not to cut or damage any 

electrical or other hidden utilities. Install the rails into the mounting channel on the housing. 

Center the mounting channel in the slots on the housing, then from inside the housing 

tighten the mounting channel nuts so the channel is securely in place. Position the housing 

in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the 

rails to the joists 

(Figure 1).

www.airkinglimited.com

6727901 Rev. G 11-18

2 of 12

SECTION 4

Ducting

NOTE: 6" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE.

CAUTION:

 

ALL DUCTING MUST COMPLY WITH LOCAL AND 

NATIONAL BUILDING CODES.

NOTE:

 The ducting from this fan to the outside of the building has a strong effect on the air 

flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible 

for best performance, and avoid installing the fan with smaller ducts than recommended. 

Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed 

with existing ducts may not achieve their rated air flow.
1. 

Connect the ducting to the fan’s duct collar 

(Figure 3).

 Secure in place using tape 

or screw clamp. Always duct the fan to the outside through a wall or roof cap. It is 

recommended that low restriction termination fittings be used.

2. 

Ensure duct joints and exterior penetrations are sealed with caulk or other similar 

material to create an air-tight path to minimize building heat loss or gain and to reduce 

the potential for condensation. Place/wrap insulation around duct and/or fan to in order 

to minimize possible condensation buildup within the duct, as well as building heat loss 

or gain 

(Figure 4).

SECTION 5

Wiring

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION:

 ALL ELECTRICAL CONNECTIONS MUST BE 

MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR 

NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING 

ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

NOTE:

 This unit includes a side access panel for wiring that does not require the removal of the 

fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove 

the blower assembly and internal wiring compartment. Both methods are equally effective.

1a.  External Wire Compartment: Remove the wire compartment cover screw and place 

cover in a secure place 

(Figure 5).

Ducting

Duct 

Collar

Figure 3

Figure 2

Joist

Housing

Joist

Mounting Rails

Figure 1

Figure 4

Insulation* 

(place around and 

over Fan Housing

Fan Housing

Power Cable*

Seal gaps 

around Housing

Round 

Duct*

Seal duct joints 

with tape

Round 

Elbows*

Wall Cap*

Roof Cap* 

(with built-in 

damper)

Keep duct 

runs short

*Purchase separately

or

Содержание D4D

Страница 1: ...ent air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code auth...

Страница 2: ...he previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 1 www airkinglimited com 6727901 Rev G 11 18 2 of 12 SECTION 4 Ducting NOTE 6 OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES NOTE The ducting from this fan to the outside of the building has a strong ...

Страница 3: ...e fan to the White Neutral wire from the power source Connect the ground wire from the house to the Green wire from the fan housing Connect the Black wire of the fan to the Black wire Hot from the power source The fan will operate on low speed continuously and boost to high upon a rise in humidity Using a properly grounded switch connect the Black wire from the supply to the input side Connect the...

Страница 4: ...10 minutes 9 times 20 minutes 1b To adjust the setting while the sensor is still flashing from Step 1a press the button the number of times that corresponds with the amount of time you desire for instance 3 times sets the delay to 5 minutes see numbers in Step 1 The sensor will then flash the number of times for the new setting 3 times before exiting back to the programming mode 2a Setting the Min...

Страница 5: ... SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these exclusions or limitations may not apply to ...

Страница 6: ...lacement Part 7 1 Grill 5S1202048 8 1 Wire Compartment Assembly 5S1250102 Specific to Model D4DG Qty Description Replacement Part 9 1 Wire Compartment Assembly 5S1250117 15 1 Grill Assembly 5S1239115 Specific to Model D4DH Qty Description Replacement Part 7 1 Grill 5S1202048 10 1 Wire Compartment Assembly 5S1250118 13 1 Knob 5S1299802 14 1 Humidity Sensor Compartment 5S1239826 Specific to Models D...

Страница 7: ...uit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et de celles des autorités locales du code c Lors de ...

Страница 8: ...es rails aux solives Figure 1 www airkinglimited com 6727901 Rev G 11 18 8 of 12 SECTION 4 Conduits NOTE UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE MEILLEURE PERFORMANCE ATTENTION TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX REMARQUE La canalisation de ce ventilateur à l extérieur du bâtiment a un effet important sur le flux d air le bruit ...

Страница 9: ...nectez le fil blanc du ventilateur au fil blanc neutre de la source d alimentation Connectez le fil de terre de la maison au fil vert du boîtier du ventilateur Connectez le fil noir du ventilateur au fil noir chaud de la source d alimentation Le ventilateur fonctionnera à faible vitesse en continu et augmentera à haute vitesse sur une hausse de l humidité Utilisez un interrupteur à terre pour reli...

Страница 10: ...inutes 5 fois 10 minutes 9 fois 20 minutes 1b Pour ajuster le réglage tandis que le capteur continue de clignoter à partir de l étape 1a appuyez sur le bouton le nombre de fois qui correspond à la quantité de temps que vous désirez par exemple 3 fois définit le délai de 5 minutes voir les numéros à l étape 1 Le capteur clignote alors le nombre de fois pour le nouveau paramètre 3 fois avant de quit...

Страница 11: ...OUS UNE GARANTIE EXPRESSE OU TACITE NE DÉPASSERA LE PRIX D ACHAT DU PRODUIT ET UNE TELLE RESPONSABILITÉ SE TERMINERA AVEC L EXPIRATION DE LA PÉRIODE DE GARANTIE Certains états et provinces ne permettent pas les limitations de la période de garantie ou l exclusion ou la restriction des dommages accidentels ou indirects et par conséquent les présentes restrictions ne peuvent pas s appliquer La prése...

Страница 12: ...D Qté Description de pièce de remplacement 7 1 Grille 5S1202048 8 1 Assemblée du compartiment du fil 5S1250102 Particularités de modèle D4DG Qté Description de pièce de remplacement 9 1 Assemblée du compartiment du fil 5S1250117 15 1 Assemblée de Grille 5S1239115 Particularités de modèle D4DH Qté Description de pièce de remplacement 7 1 Grille 5S1202048 10 1 Assemblée du compartiment du fil 5S1250...

Отзывы: