background image

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

SAVE THESE INSTRUCTIONS

www.airkinglimited.com

6727901 Rev. G 11-18

1 of 12

Exhaust Fan

Models: D4D, D4DG, D4DH, D4DGH

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN 

THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL 

INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should 

always be followed to reduce the risk of fire, electric shock and 

injury to person, including the following:

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer.If you have 

questions, contact the manufacturer.

b)  Before servicing or cleaning the unit, switch power off at service 

panel and lock the service disconnecting means to prevent power 

from being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-related construction.

b)  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 

back drafting. Follow the heating equipment manufacturer’s guideline 

and safety standards such as those published by the National Fire 

Protection Association (NFPA) and the American Society for Heating, 

Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local 

code authorities.

c)  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. 

DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE 

MATERIALS AND VAPORS.

d)  Ducted fans must always be vented to the outdoors.
e)  If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application and be connected to a GFCI (Ground 

Fault Circuit Interrupter) – protected branch circuit. 

f)  This unit must be grounded.
g)  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

h)  Read all instructions before installing or using exhaust fan.

WARNING:

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, DO NOT USE THIS FAN WITH 

ANY SOLID-STATE SPEED CONTROL DEVICE.

WARNING:

 DO NOT USE IN KITCHENS.

WARNING:

 

THE DUCTING FROM THIS FAN TO THE 

OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON THE 

AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE SHORTEST, 

STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST PERFORMANCE, 

AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN 

RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE 

ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS INSTALLED WITH 

EXISTING DUCTS MAY NOT ACHIEVE THEIR RATED AIRFLOW.

Содержание D4D

Страница 1: ...ent air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code auth...

Страница 2: ...he previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 1 www airkinglimited com 6727901 Rev G 11 18 2 of 12 SECTION 4 Ducting NOTE 6 OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES NOTE The ducting from this fan to the outside of the building has a strong ...

Страница 3: ...e fan to the White Neutral wire from the power source Connect the ground wire from the house to the Green wire from the fan housing Connect the Black wire of the fan to the Black wire Hot from the power source The fan will operate on low speed continuously and boost to high upon a rise in humidity Using a properly grounded switch connect the Black wire from the supply to the input side Connect the...

Страница 4: ...10 minutes 9 times 20 minutes 1b To adjust the setting while the sensor is still flashing from Step 1a press the button the number of times that corresponds with the amount of time you desire for instance 3 times sets the delay to 5 minutes see numbers in Step 1 The sensor will then flash the number of times for the new setting 3 times before exiting back to the programming mode 2a Setting the Min...

Страница 5: ... SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these exclusions or limitations may not apply to ...

Страница 6: ...lacement Part 7 1 Grill 5S1202048 8 1 Wire Compartment Assembly 5S1250102 Specific to Model D4DG Qty Description Replacement Part 9 1 Wire Compartment Assembly 5S1250117 15 1 Grill Assembly 5S1239115 Specific to Model D4DH Qty Description Replacement Part 7 1 Grill 5S1202048 10 1 Wire Compartment Assembly 5S1250118 13 1 Knob 5S1299802 14 1 Humidity Sensor Compartment 5S1239826 Specific to Models D...

Страница 7: ...uit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et de celles des autorités locales du code c Lors de ...

Страница 8: ...es rails aux solives Figure 1 www airkinglimited com 6727901 Rev G 11 18 8 of 12 SECTION 4 Conduits NOTE UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE MEILLEURE PERFORMANCE ATTENTION TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX REMARQUE La canalisation de ce ventilateur à l extérieur du bâtiment a un effet important sur le flux d air le bruit ...

Страница 9: ...nectez le fil blanc du ventilateur au fil blanc neutre de la source d alimentation Connectez le fil de terre de la maison au fil vert du boîtier du ventilateur Connectez le fil noir du ventilateur au fil noir chaud de la source d alimentation Le ventilateur fonctionnera à faible vitesse en continu et augmentera à haute vitesse sur une hausse de l humidité Utilisez un interrupteur à terre pour reli...

Страница 10: ...inutes 5 fois 10 minutes 9 fois 20 minutes 1b Pour ajuster le réglage tandis que le capteur continue de clignoter à partir de l étape 1a appuyez sur le bouton le nombre de fois qui correspond à la quantité de temps que vous désirez par exemple 3 fois définit le délai de 5 minutes voir les numéros à l étape 1 Le capteur clignote alors le nombre de fois pour le nouveau paramètre 3 fois avant de quit...

Страница 11: ...OUS UNE GARANTIE EXPRESSE OU TACITE NE DÉPASSERA LE PRIX D ACHAT DU PRODUIT ET UNE TELLE RESPONSABILITÉ SE TERMINERA AVEC L EXPIRATION DE LA PÉRIODE DE GARANTIE Certains états et provinces ne permettent pas les limitations de la période de garantie ou l exclusion ou la restriction des dommages accidentels ou indirects et par conséquent les présentes restrictions ne peuvent pas s appliquer La prése...

Страница 12: ...D Qté Description de pièce de remplacement 7 1 Grille 5S1202048 8 1 Assemblée du compartiment du fil 5S1250102 Particularités de modèle D4DG Qté Description de pièce de remplacement 9 1 Assemblée du compartiment du fil 5S1250117 15 1 Assemblée de Grille 5S1239115 Particularités de modèle D4DH Qté Description de pièce de remplacement 7 1 Grille 5S1202048 10 1 Assemblée du compartiment du fil 5S1250...

Отзывы: