2.  Ensure duct joints and exterior penetrations are sealed with caulk or 

other similar material to create an air-tight path to minimize building 

heat loss or gain and to reduce the potential for condensation. Place/

wrap insulation around duct and/or fan to in order to minimize 

possible condensation buildup within the duct, as well as building heat 

loss or gain 

(Figure 7).

SECTION 5

Wiring

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF 

AT SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION: 

ALL ELECTRICAL CONNECTIONS 

MUST BE MADE IN ACCORDANCE WITH LOCAL 

CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE 

UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, 

SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

1. 

Wiring Fan/Light Independently:

 Run wiring from an approved wall 

switch carrying the appropriate rating. One neutral (white), one ground 

(green or bare copper), and two hot (black lead connected to the switch). 

Secure the electrical wires to the housing with an approved electrical 

connector. Make sure you leave enough wiring in the box to make the 

connection to the fan’s receptacle.

1a.  From where you have access to inside the fan’s junction box, connect 

the one white wire from the house to both the white wire from the 

fan’s light receptacle and the white wire from the fan’s exhaust 

receptacle. Connect the first black wire from the wall switch to the 

black wire from the fan’s light receptacle. Connect the second black 

wire from the switch to the fan’s exhaust receptacle. Connect 

the ground wire from the house to the green wire from the fan’s 

receptacle 

(Figure 8).

 Use approved methods for all connections.

www.airkinglimited.com

6727919 Rev. G 11-18

3 of 12

2. 

Wiring Fan/Light together:

 Run wiring from an approved wall switch 

carrying the appropriate rating. One neutral (white), one ground (green 

or bare copper), and one hot (black lead connected to the switch). 

Secure the electrical wires to the housing with an approved electrical 

connector. Make sure you leave enough wiring in the box to make the 

connection to the fan’s receptacle.

2a.  From where you have access to inside the fan’s junction box, connect 

the one white wire from the house to both the white wire from the 

fan’s light receptacle and the white wire from the fan’s exhaust 

receptacle. Connect the black wire from the wall switch to both the 

black wire from the fan’s light receptacle and the black wire from the 

fan’s exhaust receptacle. Connect the ground wire from the house to 

the green wire from the fan’s receptacle 

(Figure 9).

 Use approved 

methods for all connections.

SECTION 6

Completing the Installation

1.  Use a sealant appropriate for contact with the building materials 

present and for the temperature requirements of the installation to 

prevent air leakage from unconditioned spaces is recommended. If 

gaps between unit housing and ceiling are great, additional material 

(backing rod, ceiling material) may be required.

NOTE: 

This fan is rated for direct insulation contact (Type IC) and it is 

recommended that this fan be completely covered by insulation in order to 

reduce heat loss or gain to unconditioned space.

2.  Reinstall the fan’s wire compartment cover. Rotate the blower wheel 

by hand to ensure it spins freely. Plug the fan’s quick connect motor 

cord into the receptacle. This cord will only fit one way into the 

receptacle 

(Figure 10).

NOTE:

 If using this fan to meet ASHRAE 62.2 requirements, locate the label 

inside the fan housing and fill in the appropriate information.

3.  Install the grill/lens/light reflector, by first removing the lens from the 

grill (there are two tabs on either side that hold the lens in place). 

Then remove the acorn nut and the lock washer which are installed 

on the reflector mounting bolt in the fan housing. Adjust the height 

of the reflector mounting bolt so that the grill will be tight up against 

the finished ceiling and less than 1/4” of the reflector mounting bolt 

protrudes through the reflector. Secure the reflector bolt’s position by 

tightening the factory installed nut against the motor clip 

(Figure 11).

Figure 10

Figure 7

Insulation* 

(place around and 

over Fan Housing

Fan Housing

Power Cable*

Seal gaps 

around Housing

Round 

Duct*

Seal duct joints 

with tape

Round 

Elbows*

Wall Cap*

Roof Cap* 

(with built-in 

damper)

Keep duct 

runs short

*Purchase separately

or

Figure 8

Supply from house

Black

Neutral (White)

Ground (Green or Bare)

Fa

n

Neutral (White)

Green

Black

By others

Red

Black

Neutral (White)

Figure 9

Supply from house

Black

Neutral (White)

Ground (Green or Bare)

Fa

n

Neutral (White)

Green

Black

By others

Red

Neutral (White)

Содержание BFQL120

Страница 1: ...including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditio...

Страница 2: ...e bottom of the fan will be flush with the finished ceiling Nail or screw the bracket in place securely Figure 3 2 Snap the fan body into the bracket Figure 4 The fan can be snapped into position with the duct collar facing to the left or the right depending which is most convenient www airkinglimited com 6727919 Rev G 11 18 2 of 12 SECTION 3 Existing Construction 1 Position housing against the jo...

Страница 3: ...wire from the fan s light receptacle and the white wire from the fan s exhaust receptacle Connect the black wire from the wall switch to both the black wire from the fan s light receptacle and the black wire from the fan s exhaust receptacle Connect the ground wire from the house to the green wire from the fan s receptacle Figure 9 Use approved methods for all connections SECTION 6 Completing the ...

Страница 4: ...quid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Section 6 Finishing the Installation to reinstall grill Cleaning the Fan Assembly Unplug the motor cord from receptacle Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER Plug the motor cord back in and restor...

Страница 5: ...NSFERS THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED TH...

Страница 6: ...lip 5S2205025 6 1 Wire Cover 5S2205040 7 1 Blower Wheel 5S2299004 8 1 Motor BFQL50 BFQLA50 5S2205035 1 Motor BFQL60 5S2205036 1 Motor BFQL70 5S2205037 1 Motor BFQL80 5S2205034 1 Motor BFQL120 BFQLA120 5S2299002 9 1 Reflector Bracket 5S2205029 10 1 Motor Bracket 5S2299003 11 1 Grill Assembly 5S9205030 12 1 Light Lens 5S2205031 13 1 6 Watt LED Lamp 5S1299725 1 11 5 Watt LED Lamp BFQLA50 BFQLA120 5S1...

Страница 7: ...onne combustion et l évacuation de gaz par le conduit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et ...

Страница 8: ...essous du ventilateur soit à effleurement avec le plafond fini Clouer ou visser solidement le support en place Figure 3 www airkinglimited com 6727919 Rev G 11 18 8 of 12 2 Fixer par pression le bâti du ventilateur dans le support Figure 4 Le ventilateur peut être fixé par pression en position avec le collet de conduit faisant face à gauche ou à droite en fonction de quelle direction est la plus p...

Страница 9: ...l interrupteur mural Fixer les câbles électriques au châssis avec un connecteur électrique approuvé Vous assurer de laisser suffisamment de câble dans la boîte pour faire le raccordement au réceptacle du ventilateur 2a Par là où vous avez accès à l intérieur de la boîte de jonction du ventilateur raccorder un fil blanc provenant de la maison aux deux fils blancs du réceptacle de la lumière et le f...

Страница 10: ...lace dans la douille Figure 12 www airkinglimited com 6727919 Rev G 11 18 10 of 12 5 Réinstallez la lentille dans le grille 6 Restaurer l alimentation et tester votre installation SECTION 7 Utilisation et entretien ATTENTION VOUS ASSURER QUE L ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION ATTENTION PERMETTRE À L AMPOULE DE SE REFROIDIR AVANT DE LA REPLACER Remplac...

Страница 11: ...els ou indirects et par conséquent les présentes restrictions ne peuvent pas s appliquer La présente garantie vous donne des droits légaux spécifiques et peut être certains autres droits qui peuvent varier selon la province La preuve d achat est exigée avant qu une réclamation de garantie ne soit acceptée SERVICE À LA CLIENTÈLE Sans frais 800 465 7300 Notre équipe de service à la clientèle est dis...

Страница 12: ... 5S2205004 4 1 Réceptacle de la Lumière 5S1201012 5 2 Clip 5S2205025 6 1 Couvercle des câbles 5S2205040 7 1 Roue de la Soufflante 5S2299004 8 1 Moteur BFQL50 BFQLA50 5S2205035 1 Moteur BFQL60 5S2205036 1 Moteur BFQL70 5S2205037 1 Moteur BFQL80 5S2205034 1 Moteur BFQL120 BFQLA120 5S2299002 9 1 Support du Réflecteur 5S2205029 10 1 Support du Moteur 5S2299003 11 1 Assemblée de grille 5S9205030 12 1 L...

Отзывы: