Air King BFQL120 Скачать руководство пользователя страница 1

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

SAVE THESE INSTRUCTIONS

www.airkinglimited.com

6727919 Rev. G 11-18

1 of 12

Exhaust Fan

Models: 

BFQL50, BFQLA50, BFQL60, 

 

BFQL70, BFQL80, BFQL120, 

 BFQLA120

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN 

THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL 

INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should 

always be followed to reduce the risk of fire, electric shock and 

injury to person, including the following:

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer.If you have 

questions, contact the manufacturer.

b)  Before servicing or cleaning the unit, switch power off at service 

panel and lock the service disconnecting means to prevent power 

from being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-related construction.

b)  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 

back drafting. Follow the heating equipment manufacturer’s guideline 

and safety standards such as those published by the National Fire 

Protection Association (NFPA) and the American Society for Heating, 

Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local 

code authorities.

c)  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. 

DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE 

MATERIALS AND VAPORS.

d)  Ducted fans must always be vented to the outdoors.
e)  If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application and be connected to a GFCI (Ground 

Fault Circuit Interrupter) – protected branch circuit. 

f)  This unit must be grounded.
g)  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

h)  Read all instructions before installing or using exhaust fan.
i)  Suitable for use with electronic speed control device.

WARNING:

 DO NOT USE IN KITCHENS.

WARNING: 

THE DUCTING FROM THIS FAN TO THE 

OUTSIDE OF THE BUILDING HAS A STRONG EFFECT 

ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE 

THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR 

BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH 

SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND 

THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD 

GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT 

ACHIEVE THEIR RATED AIRFLOW.

Содержание BFQL120

Страница 1: ...including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditio...

Страница 2: ...e bottom of the fan will be flush with the finished ceiling Nail or screw the bracket in place securely Figure 3 2 Snap the fan body into the bracket Figure 4 The fan can be snapped into position with the duct collar facing to the left or the right depending which is most convenient www airkinglimited com 6727919 Rev G 11 18 2 of 12 SECTION 3 Existing Construction 1 Position housing against the jo...

Страница 3: ...wire from the fan s light receptacle and the white wire from the fan s exhaust receptacle Connect the black wire from the wall switch to both the black wire from the fan s light receptacle and the black wire from the fan s exhaust receptacle Connect the ground wire from the house to the green wire from the fan s receptacle Figure 9 Use approved methods for all connections SECTION 6 Completing the ...

Страница 4: ...quid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Section 6 Finishing the Installation to reinstall grill Cleaning the Fan Assembly Unplug the motor cord from receptacle Wipe all parts with a dry cloth or gently vacuum the fan NEVER IMMERSE ELECTRICAL PARTS IN WATER Plug the motor cord back in and restor...

Страница 5: ...NSFERS THE PRODUCT WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED TH...

Страница 6: ...lip 5S2205025 6 1 Wire Cover 5S2205040 7 1 Blower Wheel 5S2299004 8 1 Motor BFQL50 BFQLA50 5S2205035 1 Motor BFQL60 5S2205036 1 Motor BFQL70 5S2205037 1 Motor BFQL80 5S2205034 1 Motor BFQL120 BFQLA120 5S2299002 9 1 Reflector Bracket 5S2205029 10 1 Motor Bracket 5S2299003 11 1 Grill Assembly 5S9205030 12 1 Light Lens 5S2205031 13 1 6 Watt LED Lamp 5S1299725 1 11 5 Watt LED Lamp BFQLA50 BFQLA120 5S1...

Страница 7: ...onne combustion et l évacuation de gaz par le conduit cheminée provenant d équipement de brûlage au combustible pour prévenir un refoulement Suivre les directives du fabricant de l équipement de chauffage et les normes de sécurité telles que celles publiées par la National Fire Protection Association NFPA et de la American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et ...

Страница 8: ...essous du ventilateur soit à effleurement avec le plafond fini Clouer ou visser solidement le support en place Figure 3 www airkinglimited com 6727919 Rev G 11 18 8 of 12 2 Fixer par pression le bâti du ventilateur dans le support Figure 4 Le ventilateur peut être fixé par pression en position avec le collet de conduit faisant face à gauche ou à droite en fonction de quelle direction est la plus p...

Страница 9: ...l interrupteur mural Fixer les câbles électriques au châssis avec un connecteur électrique approuvé Vous assurer de laisser suffisamment de câble dans la boîte pour faire le raccordement au réceptacle du ventilateur 2a Par là où vous avez accès à l intérieur de la boîte de jonction du ventilateur raccorder un fil blanc provenant de la maison aux deux fils blancs du réceptacle de la lumière et le f...

Страница 10: ...lace dans la douille Figure 12 www airkinglimited com 6727919 Rev G 11 18 10 of 12 5 Réinstallez la lentille dans le grille 6 Restaurer l alimentation et tester votre installation SECTION 7 Utilisation et entretien ATTENTION VOUS ASSURER QUE L ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION ATTENTION PERMETTRE À L AMPOULE DE SE REFROIDIR AVANT DE LA REPLACER Remplac...

Страница 11: ...els ou indirects et par conséquent les présentes restrictions ne peuvent pas s appliquer La présente garantie vous donne des droits légaux spécifiques et peut être certains autres droits qui peuvent varier selon la province La preuve d achat est exigée avant qu une réclamation de garantie ne soit acceptée SERVICE À LA CLIENTÈLE Sans frais 800 465 7300 Notre équipe de service à la clientèle est dis...

Страница 12: ... 5S2205004 4 1 Réceptacle de la Lumière 5S1201012 5 2 Clip 5S2205025 6 1 Couvercle des câbles 5S2205040 7 1 Roue de la Soufflante 5S2299004 8 1 Moteur BFQL50 BFQLA50 5S2205035 1 Moteur BFQL60 5S2205036 1 Moteur BFQL70 5S2205037 1 Moteur BFQL80 5S2205034 1 Moteur BFQL120 BFQLA120 5S2299002 9 1 Support du Réflecteur 5S2205029 10 1 Support du Moteur 5S2299003 11 1 Assemblée de grille 5S9205030 12 1 L...