INSTALLATION INSTRUCTIONS
CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL 

BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1.  Unpack fan from the carton and confirm that all pieces are present. In addition to 

the exhaust fan you should have:

 

 

1 - Grill

 

 

1 - Damper Assembly (attached)

 

 

4 - Mounting Rails

 

1 - Instruction/Safety Sheet  

2.  Remove the wire compartment cover by loosening the two screws holding the 

cover in place 

(Figure 1).

 

3.  Choose the location for your fan. To ensure the best air and sound performance, it 

is recommended that the length of ducting and the number of elbows be kept to a

 

minimum, and that insulated hard ducting be used. 

Larger duct sizes will reduce noise and airflow 

restrictions. This fan will require at least 8

"

 of 

clearance in the ceiling or wall, and will mount 

through drywall up to 3/4

"

 thick. The fan mounts 

between 16” on center joists using the provided 

mounting rails. 

3.  Select the most convenient electrical knockout 

and remove using a straight-blade screw driver 

(Figure 2).

SECTION 2

New Construction

1.  Install the rails on the housing and position the housing next to the joist. Line up 

housing so that it will be flush with the finished ceiling. Secure the ends of the rails 

with screws or nails (not included) to the joists and slide the housing into the final 

position 

(Figure 3).

SECTION 3

Existing Construction

1.  Set housing in position between the joist and trace an outline onto the ceiling 

material 

(Figure 4)

. Set housing aside and cut opening, being careful not to cut or 

damage any electrical or other hidden utilities. Install the rails on the housing and 

position the housing in the previously cut hole so that it is flush with the finished 

ceiling. Secure the ends of the rails to the joists 

(Figure 3).

www.airkinglimited.com

210575917 Rev. C 1-11

2 of 8

SECTION 4

Ducting

CAUTION:

 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL 

BUILDING CODES.

1.  Remove any tape that might be holding the damper in place during shipping and 

connect the ducting to the fan’s duct collar 

(Figure 5).

 Secure in place using tape 

or screw clamp. Always duct the fan to the outside through a wall or roof cap.

SECTION 5

Wiring

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL 

BEFORE STARTING INSTALLATION.

CAUTION:

 ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE 

WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE 

UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE 

SERVICES OF A QUALIFIED ELECTRICIAN.
NOTE:

 This unit includes a side access panel for wiring that does not require the 

removal of the fan’s blower assembly. If you choose to wire the unit from the inside, 

you will need to remove the blower assembly and internal wiring compartment. Both 

methods are equally effective.
1a. 

Wiring Fan/Heat Bulb(s) Independently:

 Run wiring from an approved wall switch 

carrying the appropriate rating. One neutral (white), one ground (green or bare 

copper), and two hot (black and blue). Secure the electrical wires to the housing 

with an approved electrical connector. Make sure you leave enough wiring in the 

box to make the connection to the fan’s receptacle.

1b.  From where you have access to inside the fan’s junction box, connect the white 

wire from the house to the white wire from the fan. Connect one hot (black) wire 

from the house to the black wire from the fan (this is the fan control). Connect the 

second hot (blue) wire from the house to the blue wire from the fan (this is the heat 

bulb control). Connect the ground wire from the house to the green wire from the 

fan 

(Figure 6).

 Use approved methods for all connections.

NOTE:

 On model AK927 connect the Hot (Blue) wire from the house to the two Blue 

wires from the unit.

Housing

Joist

Mounting Rails

Figure 3

Figure 2

Figure 1

Screws

Wire 

Compartment 

Cover

Figure 4

Figure 5

Figure 6

Hot (Black)

Hot (Blue)

White

Ground

From Fan

Supply from house

Содержание AK927

Страница 1: ...fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline a...

Страница 2: ...g CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES 1 Remove any tape that might be holding the damper in place during shipping and connect the ducting to the fan s duct collar Fi...

Страница 3: ...ting temperature sensing devices inside the unit may engage the ventilation fan for a time to maintain conditions inside of the unit enclosure Once conditions inside of the unit enclosure are similar...

Страница 4: ...IOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these exclusions or limitations ma...

Страница 5: ...par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les normes de s curit telles que...

Страница 6: ...gure 3 www airkinglimited com 210575917 Rev C 1 11 6 of 8 SECTION 4 Conduits AVERTISSEMENT TOUS LES CONDUITS DOIVENT TRE CONFORMES AUX CODES DU B TIMENT LOCAUX ET NATIONAUX 1 Enlever tout ruban adh si...

Страница 7: ...lateur pendant un certain temps pour maintenir la temp rature l int rieur de l unit encastr e Une fois la temp rature l int rieur de l unit encastr e est semblable la temp rature ambiante le ventilate...

Страница 8: ...sion ou la restriction des dommages accidentels ou indirects et par cons quent les pr sentes restrictions ne peuvent pas s appliquer La pr sente garantie vous donne des droits l gaux sp cifiques et pe...

Отзывы: