Air King AIDB4Y Скачать руководство пользователя страница 3

AIDB4YEF New 3-07

3 of 8

2.

Bring incoming electrical service through the romex connector
and the fan knockout. Be sure to place the connector nut over the
wiring coming into the terminal box. There are three open ports
on the terminal strip. Using a small regular screwdriver, tighten
the Neutral (white) wire of the incoming supply under the open
terminal labeled "N". Tighten the Line (black) wire of the incoming
supply under the open terminal labeled "L". Tighten the Ground
(green) wire of the incoming supply under the open terminal labeled
"  " 

(Figure 6)

. For reference, a wiring diagram is included on the

inside of the terminal box lid.

3.

Secure the incoming supply with the romex connector and replace
the fan terminal box cover.

4.

Restore power to the unit and test the installation.

SECTION 5

Finishing the Installation

1.

Included with the unit is an identifying label that must be placed
above the dryer. This label serves as a reminder that there is a
booster fan installed and that periodic cleaning must take place.

SECTION 6

Use and Care

CAUTION:

MAKE SURE POWER IS SWITCHED OFF AT SERVICE

PANEL BEFORE SERVICING THE UNIT.

1.

Fan impeller may accumulate lint. Periodic inspection, based upon
dryer usage, should be performed to ensure that the fan impeller
is not obstructed or loaded with lint. Under normal conditions, fan
should be inspected a minimum of every Six (6) Months.To inspect
and clean the impeller:

a. Disconnect the incoming power supply at the source.
b. Remove the duct from the fan inlet and remove any lint buildup

on the impeller.

c. Reconnect the duct to the fan. Turn power supply on.

NOTE:

 Excessive booster fan noise or vibration may be an indication

of lint buildup on the impeller.

2.

The fan’s bearings are sealed and provided with an internal
lubricating material, no additional lubrication is necessary.

NOTE:

 Steps 2 and 3 may be reversed.

SECTION 4

Electrical Connections

CAUTION:

MAKE SURE POWER IS SWITCHED OFF AT SERVICE

PANEL BEFORE STARTING INSTALLATION.

CAUTION:

ALL ELECTRICAL CONNECTIONS MUST BE MADE

IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL
ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF
INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A
QUALIFIED ELECTRICIAN.

NOTE:

 The fan motor, capacitor and pressure switch connections are

pre-wired from the factory.

1.

Remove the screws securing the terminal box cover plate located
on the side of the fan. All fan motor connections are prewired to
an electrical terminal strip. A 3|8" romex type cable restraint
connector will be needed to secure the wiring through the knockout
provided on the side of the terminal box

(Figure 5).

Bracket

Stud

Figure 4

Fan

Screws

Figure 3

Correct Positions

Incorrect Positions

Figure 5

Screws

Terminal Box

Supply from house

Green

Black

Ground

White

N

L

Figure 6

Black

White

Red

Brown

Blue

Black

Capacitor

kitchen

::

accessories

Call 1-800-667-8721 anywhere in the US and Canada

Air King Dryer Booster Fans at 

 

kitchen

::

accessories

U      N      L      I      M      I      T      E      D

Содержание AIDB4Y

Страница 1: ...ccordance with all applicable codes and standards including fire related construction 5 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American ...

Страница 2: ...e switch When the dryer begins operation positive pressure in the duct causes the switch diaphragm to expand closing the circuit to the booster fan An integral delay on break timer in the switch will cycle the fan on for intervals of 10 minutes This will continue until the dryer has stopped and the timer delay period has lapsed Drying cycles the booster fan the delay timer and the pressure switch ...

Страница 3: ...t and clean the impeller a Disconnect the incoming power supply at the source b Remove the duct from the fan inlet and remove any lint buildup on the impeller c Reconnect the duct to the fan Turn power supply on NOTE Excessive booster fan noise or vibration may be an indication of lint buildup on the impeller 2 The fan s bearings are sealed and provided with an internal lubricating material no add...

Страница 4: ...e faulty installation or improper maintenance will not be covered by this warranty In order to make a claim on this warranty you must be the original consumer of the product You will be required to present to Air King the original bill of sale showing date of purchase place of purchase and model purchased Failure to meet these requirements will void your warranty Air King will not be held responsi...

Отзывы: