Weekly Cleaning & Care

 WARNING: Before cleaning always turn power off and unplug the unit from outlet. 

 WARNING: DO NOT rinse Base under faucet. To clean, wipe the Base with a soft cloth.

 WARNING: DO NOT use any solvents or aggressive cleaning agents. Keep water away

 from the Air Outlet.    WARNING: DO NOT tamper with the Water Sensor.
About White Dust -Use of high-mineral content water may cause a white mineral residue to 

accumulate on room surfaces near the humidifier. The mineral residue is commonly referred to as 

“White Dust”. The higher the mineral content (the harder your water), the greater the potential for 

White Dust. The White Dust is not caused by a defect in the humidifier, but is due only to minerals 

suspended in the water from your tap.   WARNING: If you have hard tap water STOP using tap 

water and use ONLY filtered, distilled, cold boiled or bottled water to minimize the White Dust 

residue.
Tank Cleaning - Remove the Rotating Mist Nozzle from the top of the Water Tank then remove the 

Water Tank from the unit. Turn the tank upside down, unscrew the Tank Cap and drain any water 

from the tank. Wipe the tank with a soft damp cloth then

rinse it with warm water inside and out.
Base Cleaning - Gently wipe the Base with a 

soft damp cloth.
White Dust Cleaning - If mineral deposits 

“White Dust” are evident around the Ultrasonic 

Nebulizer and Water Sensor, clean these surfaces 

with a soft cloth and a small amount of undiluted 

white vinegar. If necessary, mix a solution of 50% 

white vinegar and 50% water and fill the Base with 

enough solution to cover the Ultrasonic Nebulizer (a). 

Allow it to soak for an hour and then use the provided

brush to gently loosen buildup on the 

Ultrasonic Nebulizer (b). Put 1 cup of water in the 

Base and wipe clean with a soft cloth. 

 WARNING: DO NOT rinse Base under faucet. 

Ceramic Water Filter Cleaning - Remove the 

Water Tank from the humidifier Base. Remove the  

Tank Cap (c) and rinse Ceramic Filter thoroughly with 

tap water (d), then replace on Water Tank.
Surface Cleaning - Clean all surfaces of the unit with a clean

damp soft cloth.

 WARNING: When emptying the Water Reservoir on the Base, make 

sure that the water is poured away from the Air Outlet (e). If water is 

poured into the outlet it may damage the humidifier.

a

e

b

d

c

6

 

1.  Follow all cleaning instructions prior to storage.
2.  Dry all parts, including the inside of the Water Tank.   

 

 WARNING: NEVER leave water inside the tank for several days.

3.  Leave the Water Tank cap partially loosened to prolong the life of the cap.
4.  Preferably store in its original box, in a dry place away from

  high temperatures.
5.  Follow all cleaning instructions after long periods of storage.

 

Storage 

Содержание CLEAN MIST MH-513

Страница 1: ...IM0040A READ AND SAVE THESE INSTRUCTIONS CLEAN MIST ULTRASONIC HUMIDIFIER Instruction Manual and Warranty Information...

Страница 2: ...on against harmful interference in a residential installation The product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may ca...

Страница 3: ...when fully assembled Keep out of reach of children Close supervision is necessary when this appliance is used by or near children elderly or disabled persons WARNING NEVER drop or insert any object in...

Страница 4: ...ile working silently to erase the discomforts of dry air Unpacking Specifications Product Model Power Consumption Rating Voltage Tank Capacity Dimensions Weight MH 513 30W 110 120V 60Hz 4 1L 1 1 Gallo...

Страница 5: ...5 Humidity Waterless Indicator 6 Power Mist Control Knob 7 Air Outlet 8 Cleaning Brush 9 Water Reservoir 10 Ceramic Filter 11 Tank Cap 12 Ultrasonic Nebulizer 13 Water Sensor 14 Bottom Tank Handle 3...

Страница 6: ...st Nozzle prior to filling the Water Tank Lift the Water Tank with both hands using the Handle to remove the humidifier from the Base Turn the Water Tank upside down and remove the Tank Cap by turning...

Страница 7: ...ontrol Knob clockwise until you hear a click and the Humidity Waterless Indicator turns green To turn OFF turn the Mist Control Knob counterclockwise until you hear a click and the indicator turns OFF...

Страница 8: ...t damp cloth White Dust Cleaning If mineral deposits White Dust are evident around the Ultrasonic Nebulizer and Water Sensor clean these surfaces with a soft cloth and a small amount of undiluted whit...

Страница 9: ...w unit b Dirty Water Tank or old water in tank c Minerals in well water or hard water POSSIBLE SOLUTIONS a Gently wipe the Base with a soft damp cloth b Empty old water and clean Water Tank per instru...

Страница 10: ...8 Try These Other Great Products For Your Life Available at www forlifeproducts com 8 Ultrasonic Humidifiers Air Purifiers...

Страница 11: ...nd mail back to the above address Or register your warranty online today Simply go to http www greatinnovations tv warranty php NAME ADDRESS CITY STATE ZIP TELEPHONE E MAIL DATE OF PURCHASE PLACE OF P...

Страница 12: ...Air Innovations 2015 Great Innovations LLC All Rights Reserved US International Patents Pending Available In A Variety Of Colors...

Отзывы: