background image

 

Unpacking and Inspection 

 
Immediately upon receiving the antibacterial vaporizer, carefully unpack the carton, check the 
content to ensure that all parts are present and have been received in good condition. If any parts 
appear damaged or mishandled from shipping, notify the shipper immediately and retain the 
packing material for inspection.     
 

What are included: 

 

1 x AG-1600 Antibacterial Vaporizer 

                   

1 x Wireless Remote Control 

                   

1 x Power Cord 

 

 

 

 

1 x User Manual 

 

Product Dimensions 

 

 
 
 
 
 

 

 
 
 
 
 
 
 

 
 

 
 
 
 
 

L 344 mm   

W 193 mm   

H 381 mm   

Содержание AG-1600

Страница 1: ...1 AG 1600 Antibacterial Vaporizer USER MANUAL ENGLISH ...

Страница 2: ...2 ...

Страница 3: ...mmediately unplug the machine and contact your local dealer for advice l No user serviceable and modifiable parts inside Never try to repair this product an unauthorized technician may lead the machine to damage or malfunction l For adult use only Children being supervised not to play with the machine Never leave the machine running unattended l The machine is not to be used by persons including c...

Страница 4: ...arts are present and have been received in good condition If any parts appear damaged or mishandled from shipping notify the shipper immediately and retain the packing material for inspection What are included 1 x AG 1600 Antibacterial Vaporizer 1 x Wireless Remote Control 1 x Power Cord 1 x User Manual Product Dimensions L 344 mm W 193 mm H 381 mm ...

Страница 5: ...ted power supply To determine the power requirement for the machine refer to the label on the back of the machine Always connect the machine to a protected circuit and ensure it is properly grounded to avoid risk of electrocution Step 4 Turn on the power switch Once powering up the machine it takes approximately 6 minutes to complete the warming up process to make heater reach operating temperatur...

Страница 6: ...begin to fog in the preselected mode and tap the STOP button to stop manual output To change Volume output mode tap the MENU button once while on the main menu page Date Time page use the UP TIMER and DOWN VOLUME buttons to scroll to Output Volume tap the STOP button once to toggle between Normal and High using the UP TIMER and DOWN VOLUME buttons Once you make your selection tap the STOP button o...

Страница 7: ...e timer is switched off manually by pressing the STOP button Once all settings are made press STOP button again to exit the settings menu and return to the main menu page Date Time page press UP TIMER button to trigger Timer mode and press STOP button to stop Timer mode Together the three different settings provide for an extremely flexible fogging cycle for example If you wish the AG 1600 to fog ...

Страница 8: ...is the time of day the AG 1600 will begin to fog This setting is displayed in 24 hour time and can be adjusted between 00 00 and 23 59 by using the UP TIMER and DOWN VOLUME buttons Once you have finished your selection press the STOP button once to confirm and save the settings Stop Time is the time of day the AG 1600 will stop the fogging process This setting is displayed in 24 hour time and can ...

Страница 9: ...emote Settings page Toggle between ON active and OFF inactive using the UP TIMER and DOWN VOLUME buttons Once you make your selection tap the STOP button once to confirm and save the desired setting Wireless Remote Control Operation Wireless remote control system consists of a transmitter equipped with two buttons to activate deactivate and an onboard receiver attached to the rear panel of AG 1600...

Страница 10: ...27A 12V Fluid Use Air Guard Antibacterial Solution for AG 1600 The machine is tested and calibrated with these authorized fluids to achieve the best performance Warranty will be void if any other type of liquid is used Improper use of liquid may lead to machine failure and danger Service and Maintenance Do not allow the machine and fluid to become contaminated Regularly fill distilled water to flu...

Страница 11: ...tions Input voltage Rated power Warm up time Maximum Fluid consumption Fluid tank capacity Compatible fluid Ambient temp range Output height Control Connection Dimension Weight US model AC 100 120V 50 60Hz 12A EU model AC 220 240V 50 60Hz 6A 1450W 6 minutes approx 40 ml min 2 4L 0 63gal Air Guard Antibacterial Solution 0 C 40 C 32 F 104 F 2 meters height Built in Calendar Manual Wireless Remote Ti...

Страница 12: ...12 M22 Moisture Co Ltd Tel 886 3 2227470 Fax 886 3 2227469 www airguard com tw e mail sales airguard com tw C08AG1601 ...

Отзывы: