REVERSE OSMOSIS

AIR GAP

Model:

Old Part Number: 

500 Jefferson Street, Placentia, California 92870 USA • 949-955-3928 • Email: [email protected] 

Copyright  AIR GAP INTERNATIONAL 

Placentia, California

AG110-001

GAP-A-RO, KIT S-A

Doc.#400-0653-003

5. Connect 3/8" OD poly tubing from
your RO unit to AG110-001 inlet
port and 3/8" OD poly tubing from the
AG110-001 outlet port to the drain
pipe. Use provided clamps and
screws to secure tubing. (See FIG
1-5)

3/8” O.D.

Poly tubing

Also fits

 5/8” I.D. Poly tubing

The 5/8 inch ID tubing fits
AG110-001 and can be used if
desired. The AG110-001 design
enables the larger tube to be
used for inlet or outlet, or to be
as part of a double-sealed
system, or to provide added
mechanical protection to the
inside tubing. (See FIG 1-6)

5/8” I.D. Poly

tubing

4. The AG110-001 must be installed with the "C/L" line
above the sink's rim, sump, floor drain, floor grate, or
standpipe where the discharge tubing is terminated. The
AG110-001must be installed vertically. Secure
AG110-001 with provided mounting screws (See Fig 1-4).

"C/L"

0.857"-0.900"

Critical Level (C/L) marking 

Mounting Screws

Fig 1-4

3/8” O.D.

Poly tubing

Clamp

Fig 1-5

Fig 1-6