87
Installation and Maintenance
Service Manual
12. Remove 4-way valve assy
13.remove the isolation plate and gas-liquid separator
Remove the 2 screws connecting the isolation
plate and condenser side plate; remove the
3 screws connecting the isolation plate and
chassis, and then remove the isolation plate
and gas-liquid separator.
screw
screw
isolation plate
Procedure
Steps
14.Remove compressor
damping
cushion
compressor
Remove the 3 foot nuts fixing compressor
and then lift the compressor upwards to
remove the compressor and damping
cushion.
Note:
Keep the ports of discharge pipe and
suction pipe from foreign objects.
4-way valve
spot
spot
Inhalation tube
Discharge tube
gas-liquid separator
Unsolder the spot joints connecting the 4-way
valve assy with capillary sub-assy, compressor and
condenser; remove the 4-way valve.
Note:
Before unsoldering the welding joint, wrap the 4-way
valve with a wet cloth completely to avoid damage to
the valve caused by high temperature.