background image

BULB REPLACEMENT PROCEDURE

WARNING:

 TURN OFF THE UVC MAX 

25 AND UNPLUG THE 710 VOLT MODEL 

OR SHUT OFF THE AIR HANDLER FOR 

THE 24 VOLT MODEL BEFORE START-

ING REPLACEMENT PROCEDURE. 

WARNING:

 UNPLUG UNIT FROM 

OUTLET BEFORE COMMENCING 

INSPECTION AND CLEANING. 

WARNING:

 

NEVER TOUCH BROKEN BULBS OR INTERNAL CONTENTS OF A BULB.  

THESE PARTS CONTAIN MERCURY 

NOTE:

 WEAR DISPOSABLE, NON-

ABSORBENT PROTECTIVE GLOVES 

PRIOR TO INSPECTION PROCEDURE  

IN CASE OF ACCIDENTAL BREAKAGE 

OF GLASS.

NOTE:

 

 

WEAR DISPOSABLE, NON-

ABSORBENT PROTECTIVE GLOVES 

PRIOR TO INSPECTION PROCEDURE IN 

CASE OF ACCIDENTAL BREAKAGE OF 

GLASS.

NOTE: 

IF BLUE LIGHT LEAKS 

THROUGH ANY PORTION OF PLENUM 

AND/OR AROUND MOUNTING PLATE, 

TURN OFF THE FV/AX 25 IMMEDIATELY 

AND SEAL AFFECTED AREAS AND/

OR ROTATE POWER UNIT AND REPEAT 

STEPS AS NEEDED 

NOTE: 

IN CASE OF ACCIDENTAL EXPOSURE TO INTERNAL CONTENTS OF 

BULB, WASH HANDS AND ANY OTHER AFFECTED SKIN AREA WITH MILD 

DETERGENT. REMOVE AFFECTED CLOTHING IMMEDIATELY IF SKIN SURFACE 

IS PIERCED, SEEK MEDICAL ATTENTION IMMEDIATELY 

1. Loosen mounting screws.

2. Remove the unit from the duct.

3. Remove the old bulb from the socket.

4. Install replacement bulb into socket. Do not handle the 

bulb with bare hands. Oils on the hands tend to reduce bulb 

life. Verify bulb is secure in socket so it will not fall out into 

the duct.

5. Wipe off the glass with lsopropyl alcohol and a lint free 

wipe.

6. Re-attach the unit to the duct with 4 mounting screws.

7. After unit MAX 25 is firmly in place, plug the 110 Volt 

version power cord into a standard electrical wall outlet and/

or restore power to the Air handler for the 24 Volt version. 

Check bulb operation by looking through the view porthole. A 

blue glow should be seen in the duct.

1. We recommend inspecting and cleaning bulb at 
least every 6 months depending upon your home 
environment and condition of conventional filters 
and duration of use and their replacement cycle.

2. To maintain the bulbs maximum output intensity, 
replace your UVC Max 25 Air Purifying System 
bulb annually, depending upon your home 
environment using the replacement procedure 
below. The bulb should operate continuously for 
maximum bulb life and light effectiveness.

UV bulbs contain a small amount of mercury, 

like a typical fluorescent bulb. Check with your 

local waste management authority for local 

disposal or recycling requirements.

MAINTENANCE

Содержание UVC MAX 25

Страница 1: ...UVC MAX 25 WHOLE HOUSE AIR PURIFYING SYSTEM USER MANUAL...

Страница 2: ...or sheet metal Electrical shock can cause personal injury or death Never expose eyes or skin to direct UVC light from any source This product is designed for indoor installation only i e attics crawl...

Страница 3: ...Never expose eyes or skin to UVC light from any source Looking directly at the UVC light may cause permanent eye damage or blindness Never operate the UVC MAX 25 out of the plenum Avoid touching the...

Страница 4: ...FAN FAN FAN AIR FLOW FAN AIR FLOW AIR FLOW AIR FLOW HORIZONTAL FLOW UP FLOW DOWN FLOW DOWN FLOW FAN FAN FAN AIR FLOW FAN AIR FLOW AIR FLOW AIR FLOW HORIZONTAL FLOW UP FLOW DOWN FLOW DOWN FLOW FAN FAN...

Страница 5: ...socket Do not handle the bulb with bare hands Oils on the hands tend to shorten bulb life Figure 2 6 Mount the Max 25 onto the plenum with the supplied self tapping sheet metal screws Figure 3 7 Plug...

Страница 6: ...e loose piece of duct board Figure 2 Place mounting plate over the access hole Figure 3 Now bend the mounting plate upper and low er tabs 90 degrees and with the rectangular opening in the plate close...

Страница 7: ...N O TLIG H TU PAFTER REPLAC IN GBU LB REPLAC EU N IT C L E A N U PO FB R O K E NB U L B S UVC bulbs contain a small amount of mercury like a typical fluorescent bulb DO NOT TOUCH any of the mercury wi...

Страница 8: ...he duct 3 Remove the old bulb from the socket 4 Install replacement bulb into socket Do not handle the bulb with bare hands Oils on the hands tend to reduce bulb life Verify bulb is secure in socket s...

Страница 9: ...y additional expedited service charges for quicker shipping shall be born by the purchaser If the product or component is not found to be a warranty issue the purchaser will be responsible for return...