- 1 - 

 

 
 

Sentinel 1500 

Air Scrubber 

    

    

    

    

    

    

    

CONTENTS 

Unpacking/Safety --------------------------  2 
How & When to use an Air Scrubbers --- 3 
Maintenance --------------------------------- 7 
Calculate Number of Units per Project -- 7 

Specifications

 ---------------------------------- 8 

Parts List ------------------------------------ 9 
Locations ---------------------- ------------ 10 
Glossary ------------------------------------ 11 
Warranty ----------------------------------- 12 

Air-Care is a Division of D.P.L. Enterprises, Inc. 

3868 E. Post Road, Las Vegas, NV 89120 (702) 454-5515, Fax (702) 454-5225 

Website: www.air-care.com, E-mail: [email protected] 

Revised 11/15/2012       

P/N  MM0156 

Item # FG0157 

Содержание FG0157

Страница 1: ...culate Number of Units per Project 7 Specifications 8 Parts List 9 Locations 10 Glossary 11 Warranty 12 Air Care is a Division of D P L Enterprises Inc 3868 E Post Road Las Vegas NV 89120 702 454 5515...

Страница 2: ...n the 3 filters there are no user serviceable components in the Air Care Sentinel Air Scrubber Only trained technicians should attempt to make internal repairs on this equipment Always turn off the ma...

Страница 3: ...a specific piece of hardware When should you consider using one or more of these devices There are only a few universal regulations or standards but to say it is all guesswork is not at all true On a...

Страница 4: ...between 1 and 2 and 02 W G between Zone 2 and 3 Measuring from Zone 1 to Zone 3 should find 04 W G The pressure drop should be maintained at 02 W G between a contained and an uncontained area This can...

Страница 5: ...he area Remember the recommended air exchange rate is from 4 to 12 air changes per hour If this area requires a higher pressure difference you may need to go as high as 12 changes per hour which means...

Страница 6: ...from place to place to be cleaned It may seem a bit overwhelming at first glance but the methods developed for containing airborne Asbestos fibers during 35 years of abatement are well proven and easi...

Страница 7: ...5 The NORMAL pressure reading with the 4 dia Restrictor Plate installed is 4 4 When planning the number of pre filters to have on hand for a job that involves heavy demolition with significant dust an...

Страница 8: ...Inlet and 12 Dia Exhaust collar Operating Environment 25 to 125 Deg F 4 to 50 Deg C Construction Rotation Molded Poly lower body and Vacuum Formed top Operating Controls Single Plug able Panel with a...

Страница 9: ...OL0026 12 12 Non Marking Wheels 2 ACC0006 11 Front Locking Swivel Casters 2 COM0096 Not Shown Bottom Carrying Handle Spring Loaded COM0029 Panel Gauge 0 to 5 W C COM0033 Panel Power Receptacle COM0026...

Страница 10: ...10...

Страница 11: ...13 Fiberglass Filter A disposable very low efficiency filter approx 10 arrestance 14 Flex duct Plastic fabric duct with a spiral wire support It us used extensively in the Western U S 15 HEPA High Ef...

Страница 12: ...will be handled on an individual basis General Conditions This warranty shall be held void on any Air Care equipment which has been modified or altered in any way or which has been subject to imprope...