background image

 

Troubleshooting Guide 

 

Prior to troubleshooting, check the following

1.  Be sure power cord is plugged in, AND the Breaker/switch is in the “ON” with the Light Lit. If there 

is no light, try another outlet. 

2.  When testing the motor use the remote switch to turn the motor on for the first test. 
3.  For testing leave the Speed at the Lowest Setting (1).  
4.  It is SAFER to run the COBRA VI with the cable end DISCONNECTED. You will be told when to 

attach it. 

Problem 

Check 

IF 

 Action 

Motor does not 
run. 

1. Did you follow the first 5 
steps at the top of this page? 

Yes 
 
No 

Be sure the Brush and Cable have been 
disconnected and Go to #2 
Follow the 5 instructions above then go to 
#2. 

Motor does not 
run 

2. Does the RED LED on the 
remote flash when the buttons 
are pushed?  

Yes 
No 

Go to #3 
The Remote may have a dead battery, 
Replace the 2- “AA” batteries and repeat 
the test. If it still does not light, go to #4 

Motor does not 
run 

3. Turn the Motor “ON” with the 
Remote START button then 
Press “Change Rotation”. Does 
the motor run in BOTH 
directions? 

Yes 
 
 
No 

The motor is good, but the remote is failing, 
Call Air Care.  
 
Go to #4 

Motor Does not 
run 

4. Use the Panel START switch 
and Change Direction Switch, 
and count to 4 to give it time to 
respond. Did Motor Run? 

Yes 
 
No 

The Remote appears to be failing, Call Air 
Care. 702-454-5515  
Contact Air-Care for advanced Diagnostics. 
702-454-5515  

Brush Speed 
does not 
change 

5. Press the PANEL “START” 
switch. Does the Motor start to 
run at any speed? 

Yes 
No 

Go to #7 
If the “Speed Indicator” lights on the Panel 
change? Contact Air-Care Tech Support. 

Brush Speed 
does not 
change 

6.  Does the Motor Start Light 
turn on after Pressing 
“START”? 

Yes 
 
No 

Go to #7 
 
Contact Air-Care Tech Support 

Brush Speed 
does not 
change 

7. Press the Speed Increase 
button (+) and the Speed 
Decrease button, (-) several 
times. Does the Light Change 
on the Panel Speed Indicator? 

Yes 
 
 
No 

Attach the Cable and brush and verify that 
the Brush Speed changes with the Button. 
Go to #8 
 

Brush Speed 
does not 
change 

8. Does the Brush Speed 
change when the Speed is 
increased and decreased. 

Yes 
No 

Repeat Test with the Remote. 
Contact Air Care Tech Support. 

Motor Runs 
until Cable and 
Brush Installed 

9. Is the Cable coiled tightly or 
is this brand new cable? 

Yes 
 
 
No 

When being used, the cable must be coiled 
loosely, about 24” diameter or larger coils. A 
new cable must “break in” a few hours. 
Go to #10 

Motor Runs 
until Cable and 
Brush Installed 

10. Is the Large 36” brush 
attached? 
 

Yes 
 
No 

The 36” brush should only be run at speeds 
of Lowest and Med Slow (1 and 2)  
Contact Air-Care Tech Support 

Final Test Run 

11. Did the COBRA VI run 
properly in all modes? 

Yes 
 
No 

Problem solved. A power surge may have 
tripped the breaker. 
Look for the new symptom in the left column 
or call Air-Care Tech Support. 702-454-
5515 

   

Содержание COBRA-VI

Страница 1: ...lter Association COBRA VI Power Brush System MM0206 Revised 25Jun2016 Table of Contents Unpacking Safety information 2 Operating Instructions 3 Duct Cleaning with COBRA VI 4 Component Names Locations...

Страница 2: ...ns should attempt to make internal repairs on this equipment Call Air Care 800 322 9919 for tech Support Never use the COBRA VI in a wet environment Always turn off the main power switch Breaker on th...

Страница 3: ...rol panel The brush will be started in its LOWEST speed If a new brush cable is still rolled up tighter than a 30 diameter it may not turn due to internal friction Open up the size of the coiled cable...

Страница 4: ...Bristle Brush into the duct with a smooth gentle force The brush will expand and compress to clean any size duct from 4 to 18 high and any width CAUTION To clean duct board ducts or older flex duct sy...

Страница 5: ...5 COBRA VI Components...

Страница 6: ...6 COBRA VI Standard Accessories Optional Accessories...

Страница 7: ...fitted with other length and diameter bristles for special applications Optional SACOB0005 9 18 Replacement Bristles Standard Bristles 18 x 021 diameter 5 changes Optional BA0006 10 Handle Coil n Carr...

Страница 8: ...Air Care 702 454 5515 Contact Air Care for advanced Diagnostics 702 454 5515 Brush Speed does not change 5 Press the PANEL START switch Does the Motor start to run at any speed Yes No Go to 7 If the S...

Страница 9: ...nd on the 3 8 dia cable core Be sure to reinstall the washer onto the end of the cable before the replacement end 7 Tighten the collar set screws alternately a little at a time until the collar is hol...

Страница 10: ...t from the air while the clean air move freely through it 17 EPA Environmental Protection Agency 18 Duct A metal plastic or fiberglass tube that transports air to and from the Air Handler They can be...

Страница 11: ...s facility for evaluation If found to be defective and covered by the terms of this warranty Air Care will pay FedEx ground shipping charges on the repaired or replaced item back to the purchaser s lo...

Отзывы: