Troubleshooting Guide 

 

Prior to troubleshooting, check the following

1.  Be sure power cord is in the power inlet on the COBRA-5 Motor Case Panel, AND the switch is in 

the “ON” or “1” position. The LED should be on, if not try another outlet. 

2.  When testing the motor, select “Remote” for FORWARD or REVERSE, and use the remote 

switch to turn the motor on for the first test. 

3.  Set the speed control on the front of the motor case to “40”. 

4. 

It is SAFER to run the COBRA-5 with the cable end DISCONNECTED. You will be told when to 
attach it.

 

Problem 

Check 

IF 

 Action 

Motor does not 
run. 

1. Did you follow the first 5 
steps at the top of this page? 

Yes 
 
No 

Be sure the Brush and Cable have been 
disconnected and Go to #2 
Follow the 5 instructions above then go to 
#2. 

Motor does not 
run 

2. Turn the Motor “ON” with the 
Remote switch in FWD Then 
switch to REV. Did the Motor 
Run in BOTH directions? 

Yes 
 
No 

Go to #3 
 
The Remote switch may defective, call Air-
Care 

Motor does not 
run. 

3. Switch the “FWD / REV” 
selector to “PANEL” and flip the 
“FWD/REV” switches to 
Forward then Reverse. Does 
the Motor run? 

Yes 
 
 
 
No 

The Remote Switch may be defective, call 
Air-Care. 
 
 
Go to #4 

Motor Does not 
Run 

4.  Does the Motor HUM when 
turned on? 

Yes 
 
No 

Call Air-Care. 
 
Go to #5 

Motor does not 
run. 

5. Check the circuit breaker on 
the panel, has it popped up? 

Yes 
 
 
No 

Reset the circuit breaker and try the motor 
again. Go to #6. 
 
Call Air-Care 

 

6. Does the circuit breaker trip 
every time the motor is turned 
on in forward and reverse? 

Yes 
No 

Call Air-Care 
Run a full test in forward, reverse, fast and 
slow, 
If it runs OK, attach the brush and cable and 
run in all modes, then go to #7. 

 

7. Did the COBRA-5 run 
properly in all modes? 

Yes 
 
No 

Problem solved. A power surge may have 
tripped the breaker. 
Look for the new symptom in the left column 
or call Air-Care 

The Brush 
slows down 
when set to 
#100 on speed 
Control 

8. Is the Cable coiled tightly or 
is this a brand new cable? 

Yes 
 
 
No 

When being used, the cable must be coiled 
loosely, about 24” diameter or larger coils. A 
new cable must “break in” a few hours. 
Go to #10 

 

9. Is the Large 36” brush 
attached? 
 

Yes 
 
No 

The 36” brush should only be run at speeds 
of 5 and lower. 
Go to #11 

 

10. Is the standard cable being 
used (3/8” Core) 

Yes 
No 

Be sure the torque switch is set to “High”  
Call Air-Care 

The Dryer 
Cable (5/16”) 
twists 

11. Is the torque switch set to 
“LOW” 

Yes 
No 

Call Air-Care 
Set the torque switch to LOW and test 
again. 

Содержание COBRA-5

Страница 1: ...A National Air Duct Cleaners Association COBRA 5 Power Brush System Revised 3Feb2014 P N MM0122 Table of Contents Unpacking Safety information 2 Operating Instructions 3 Duct Cleaning with COBRA 5 4 D...

Страница 2: ...omponents in the COBRA 5 only trained technicians should attempt to make internal repairs on this equipment Never use the COBRA 5 in a wet environment Always turn off the main power switch on the COBR...

Страница 3: ...nut onto the 2 diameter threaded end of the coupler This nut should be snug but NOT excessively tight 6 The FWD REV switch on the panel and remote should be in the center or Off position 7 Hold the o...

Страница 4: ...compress to clean any size duct from 4 to 18 high and any width CAUTION To clean duct board ducts or older flex duct systems the COBRA 5 Brush system should be used at a low speed with caution as its...

Страница 5: ...and pushing it in again 8 If the cable cannot be pushed all the way to the end of the duct it may be necessary to insert the cable and brush from the other end of the duct 9 If there is a visible lint...

Страница 6: ...itch Circuit Breaker Brush Cable Connector Remote Switch Cable storage FWD OFF REV Speed Control Power Inlet Computer type Panel Switch Cable FWD OFF REV Power LED Selector Switch for FWD OFF REV For...

Страница 7: ...for 4 18 ducts 3 8 x 35 Standard Cobra Cable with 18 Brush Dryer Duct Cleaning DVD Dryer Duct Nest Claw Dryer Exhaust Vent Flap Clip Anemometer Air Flow Meter 5 16 Dryer Duct Cable Includes 4 Dryer D...

Страница 8: ...BA0006 10 Handle Coil n Carry YES FG0102 11 Power Cord 9 foot YES EC0012 12 Dryer Duct Brush 4 w Lint Buster Ball Optional FG0072 13 Cable Housing OD for 3 8 Core Optional COM0022 14 Nest Claw for Dr...

Страница 9: ...tch may be defective call Air Care Go to 4 Motor Does not Run 4 Does the Motor HUM when turned on Yes No Call Air Care Go to 5 Motor does not run 5 Check the circuit breaker on the panel has it popped...

Страница 10: ...e collar set screws alternately a little at a time until the collar is holding the split end on the end of the cable securely 8 The cable is now ready for testing It should perform like new If you hav...

Страница 11: ...t from the air while the clean air move freely through it 17 EPA Environmental Protection Agency 18 Duct A metal plastic or fiberglass tube that transports air to and from the Air Handler They can be...

Страница 12: ...cility for evaluation If found to be defective and covered by the terms of this warranty Air Care will pay FedEx ground shipping charges on the repaired or replaced item back to the purchaser s locati...

Отзывы: