Aiphone TC-NMD TC-10MD Скачать руководство пользователя страница 1

n

Master Station with Selective Door Release

TC-10MD 10-Call Master

TC-20MD 20-Call Master

- SUPPLEMENT TO TC-M INSTRUCTIONS -

The TC-MD Intercom and Selective Door Control System is designed for communication between a central master 
station and remote door stations.  

The TC-MD adds door release to the standard TC-M system.

All information 

regarding installation other than the external control functions is included in the TC-M instructions.  In addition to 
communication to remote locations, the Master Station can selectively release the corresponding door strike or 
maglock.

WIRING DIAGRAM:     SYSTEM USED FOR SELECTIVE DOOR RELEASE

Individual Components for System:

TC-

n

MD

Master station with selective contact output capability (10, 20)

RY-PA

Relay for selective output (1 per station requiring external contact)

PS-1820UL

18V DC, 2A Power Supply

TB-AD1

1 Audio Door Adaptor

TB-AD10

10 Audio Door Adaptor

TB-ADM10

10 Video Door Adaptor

IMPORTANT:

1.   RY-PA must be used for each selective contact to 

isolate AC voltage from the intercom circuit.

2.

Extra contact connections and L are on the  
external terminal block. 

Pg. 1

TC-MD TERMINAL DEFINITIONS:

+

Power input  (18V DC or 16V AC)

-

Negative

1~10

Station number

E

Common communication

M,C

Master-to-Master communication

T

Transmit to door station

R

Receive from door station

S, S

Output to call extension speaker

SEPARATE TERMINAL BLOCK LOCATED INSIDE MASTER:

1~10 (20) Selective negative for each channel
L

Common Positive output for selective closure

TC-10MD

+

-

PS-1820UL

TB-AD1

For Door #9

1
2

IE/IF Door 

Station

1
2

N

T

R

+

-

1
2

N

T

R

+

-

1
2
3
~
9

10

E

T

R

12+

12-

M

C

AC/

DC

Input

TB-AD1

For Door #10

1
2

IE/IF Door 

Station

Door Release button

Located below 

TRANSFER button.

TC-20MD

x     x

RY-PA 

#1

RY-PA 

#9

RY-PA 

#10

BLK

BLK

BLK

YEL

YEL

YEL

Relays are activated 
when the door 
release button is 
being pressed while 
a station button is 
selected.

Momentary Closure for Station #1

To convert RY-PA to N/C (normally 
closed) contact:  Move one yellow wire 
from "NO" to "NC".  (Internal 
modification, soldering required.)

AC Power 

for Door 

Releases

Common for each closure

Momentary Closure for Station #9

Momentary Closure for Station #10


~
9

10

L