– 7 –
NHR-4A
NHR-3A-4
Press TONE-OFF button.
(No communication)
Bathroom
call
Pull down
NHR-SP
NHX-50M
NHR-7A
NHR-8A
NH-1SA,
NH-1SA/A,
NH-2SA,
NH-2SA/A
Bathroom Call
Step
Stations
Tone Light
Operations
1.
Bedside sub station
–
–
Bathroom pullcord
–
Red LED lit
Initiator: Pull down cord.
2.
Corridor lamp
–
Red lamp blinking
2.
Zone light
–
One lamp is lit (1~4).
2.
Master station
Single chime
Sub call-in LED (red)
every 2 sec.
blinking, every 1.8 sec.
2.
Duty station
Single chime
CALL blinking red
Press TONE-OFF button and go to master
every 2 sec.
every 1.8 sec.
or room.
3.
Attendant
Press TONE-OFF button.
(Master station)
Go to the Sub station.
4.
Bedside sub station
Attendant:
Bathroom pullcord
Move switch up to reset the call.
Bathroom call is an urgent call originated from bathroom pullcord switch, wired to each Bedside sub station.
The call-in lights on the same bedside sub station selector, but LED blinks twice as fast on the same LED.
Duty station
Master station
Zone light
Corridor lamp
Bedside
Bathroom
sub station
pullcord
Blinking LED & Tone
Stations
Tone Light
–
–
–
–
Single chime
Single chime
CALL blinking red
every 1.8 sec.