![Aiphone MKS-2MCD Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/aiphone/mks-2mcd/mks-2mcd_specifications_2873230002.webp)
SPECIFICATIONS:
System:
MKS-2MCD (MK-DAC, MK-2MCD, PS-1820UL)
Power Source:
18V DC. Use PS-1820UL.
Operating Temperature:
MK-DAC, DBC, DGC: 14
°
~ 140
°
F
MK-2MCD/2HCD: 32
°
~ 104
°
F
Communication:
Hands free at door station, Handset at monitor station
Calling:
From Door to Inside: Chime tone with “Instant on”
Between Inside Stations: All Call tone, then communicate with handset
Video Monitor:
4” CRT with 525 scanning lines
Camera Unit:
CCD (Charged Coupled Device) with infrared LED illumination
Overall Viewing Area:
36” Vert. x 72” Horiz. at 20”
Wiring:
2 wires to door station(s) (Use Aiphone wire # 841802)
4 wires between monitors (Use Aiphone wire # 841804)
Wiring Distance:
Door station to MK-2MCD: 165’ w/22AWG; 330’ w/18AWG
MK-2MCD to farthest MK-2HCD: 245’ w/18AWG (Doubling power wires)
PS-1820UL to MK-2MCD: 16’ w/18AWG
Mounting:
Surface mount to a 1-gang box or ring
Door Release Contact:
Normally Open - 12V AC, .4A Max.
Dimensions (H x W x D):
8-1/4” x 8-1/4” x 2-3/4”
MOUNTING & INSTALLATION:
System Layout Example:
MK-2MCD
MK-DAC
PS-1820UL
Aiphone Communication Systems • 1700 130th Ave. NE • Bellevue, WA 98005
(425) 455-0510 • FAX: (425) 455-0071 • (800) 692-0200 • www.aiphone.com
MK-2HCD
MK-DBC
2
2
4
2
MK-2SD
4
0903
MK-2MCD/MK-2HCD
MK-2SD
MK-DAC