Pg. 2

LA-20,40AS Instr.

1098mkjd

TOLL FREE TECHNICAL SUPPORT:

(800) 692-0200

TOLL FREE FAX LINE:

(800) 832-3765

TECHNICAL SUPPORT E-MAIL:

[email protected]

WIRING DIAGRAM:

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA  98005
(425) 455-0510
FAX (425) 455-0071

CAUTION

* Do not connect any AC wires to any terminal on any unit, as fire or unit damage may occur.  Connect only
  specified power source on +, - terminals.
* Do not install more or different power sources than specified for the system.
* Do not attempt to install or connect wires on LAF-C system while the system's power supply is plugged in.
* L-nAS add-on selectors  and related equipment, unless specified as "weather resistant", are designed for indoor
  use only.Door stations (LE-D, LE-DA, LE-DL, LS-NVP-W) may be installed outdoors.

IMPORTANT

* There is no need to disassemble the equipment for installation. Do not access the PC boards inside the units
unless
   properly qualified.
* Any other manufacturer's products installed with the system (power supply, external signalling device, etc.) are
  not covered under Aiphone's warranty.
* Do not mount L-

n

AS equipment in the following places, as it may cause the system to malfunction:

- High or extreme cold temperature areas: under direct sunlight, near equipment that varies in temperature,
   in front of air conditioner, inside a refrigerated area, etc.
- Places subject to moisture or humidity extremes.
- Places subject to environmental conditions, such as dust, oil, chemicals, salt, etc.

* L-

n

AS units are electronic devices, which must not be subjected to water or any other liquid.

* Severe weather conditions, such as lightning storms, may cause damage to LAF-C equipment.  We recommend
   that power surge protection be installed to minimize potential component level damage.

- Additional SA-1 surge arrestors should be installed on all communication lines (one SA-1 for every two
   wires connected to master.)  See SA-1 instructions for further information.

For additional information about this system,

please refer to the LAF-C  instructions.

1
2
3

~

20

E

-

R

X1
X2
X3
X4
X5
X6
X7
X8

+

-

LAF-20CA

+

-

PS-12C

LE-D

1

E

-

LE-D

LE-D

1

E

-

1

E

-

LA-40AS

1
2
3

~

40

WIRING NOTE:

The following sub stations
are wired as shown above:
  · LE-A, LE-AN
  · LE-B, LE-BN
  · LE-D, LE-DA

Blk
Yel

Org
Gry

Brn

Red
Wht

Grn

Wiring from

Add-on Selector

LE-DA

1

E

-

LE-DA

1

E

-

NOTE:

LA-20AS wires
the same as
shown here.