7
4
Supplying power to sub master stations via a distribution adaptor
* The total wiring distance of residential stations is 300 m (980').
PS24
PS24
PS24
*1
*2
*1: The master station needs a power supply.
*2: Up to four sub master stations can be supplied with one power supply. Use two power supplies for 5 - 7 sub master stations.
5
Mix-and-match methods
* The total wiring distance of residential stations is 300 m (980').
PS24
PS24
Wiring distance
CAT5e
(24AWG)
Wire diameter
Notes
Ø0.65 mm
(22 AWG)
Ø0.8 mm
(20 AWG)
Ø1.0 mm
(18 AWG)
Ø1.2 mm
(16 AWG)
[A]
-
5 m (16')
5 m (16')
10 m (33')
10 m (33')
-
[B]
300 m (980')
-
-
[C]
-
150 m (490')
200 m (650')
300 m (980')
300 m (980')
When powering up to one master station and four sub master
stations
[D]
-
150 m (490')
200 m (650')
300 m (980')
300 m (980') When powering up to six sub master stations
[E]
30 m (98')
-
Up to 50 m (165') when powering master and one sub master
stations
[F]
30 m (98')
-
When powering up to three sub master stations
[G]
50 m (165')
-
When powering up to two sub master stations
[H]
-
5 m (16')
5 m (16')
10 m (33')
10 m (33')
When powering up to three sub master stations
[I]
200 m (650')
-
-
[J]
-
150 m (490')
200 m (650')
300 m (980')
300 m (980') -
[K]
50 m (165')
-
-
[L]
-
5 m (16')
10 m (33')
10 m (33')
10 m (33')
-
[A]
[K]
[L]
[I]
JP-8Z
[A]
[K]
[E]
[E]
JP-8Z
[L]