13
Before Using
Camera View Range and Mounting Position
2
Camera View Range and Mounting Position
Camera view adjustment
The camera angle can be adjusted downward (0 to -20 degrees) using the camera angle adjustment lever. Set the
angle to the optimal position.
Camera view range
The camera range as illustrated is only an approximate indication and may vary according to the environment.
• Example: Installed on table
Installed on a flat desktop (with desktop stand at 45°, camera angle at the lowest position (-20°))
• Example: installed as a reception station
Installed on a flat desktop (with desktop stand at 30°, camera angle at the lowest position (-20°))
• Example: Installed on a wall
-20°
0°
Camera angle adjustment lever
Rear
460mm(1' 6'')
500mm(1' 7'')
400mm(1' 4'')
500mm(1' 7'')
700mm(2' 3'')
1,300mm(4' 3'')
900mm(2' 11'')
height of desk
Vertical
Horizontal
500mm(1' 7'')
950mm(3'1")
1,850 mm(6'1")
600 mm(1'12")
1,250 mm(4'1")
height of desk
Vertical
500
mm
(1' 7'')
350mm(1' 2'')
1,750mm(5' 9'')
1,400mm(4' 7'')
500
mm
(1' 7'')
1,550mm (5' 1'')
350mm(1' 2'')
1,200mm (3' 11'')
500mm(1' 7'')
460mm(1' 6'')
Vertical
Horizontal
Camera angle 0°
Camera angle -20°
A*
1
B*
2
A*
1
B*
2
*
2
B: Camera position 1575.5mm (5' 2'')
*
1
A: Center of device 1,500mm (4' 11'')