<Wall mounting>

Camera angle -20°

Horizontal

500mm

(1' 7'')

350mm (1' 2'') 

1400mm (4' 7'')

Center

of device

1,500mm 

(4' 11'')

Camera

position

1575.5mm

(5' 2'')

Vertical

Camera angle 0°

1750mm (5' 9'')

Center

of device

1,500mm 

(4' 11'')

Camera

position

1575.5mm

(5' 2'')

500mm

(1' 7'')

350mm (1' 2'') 

1200mm (3' 11'')

1550mm (5' 1'')

500mm 

(1' 7'') 

460mm (1' 6'') 

When light enters the camera, the monitor screen may flicker brightly or the subject may become dark. Try to prevent strong lighting from entering the 

camera directly.

How to Connect

Connection Precautions

 

Cat-5e/6 cable

•  For connection between devices, use a straight-through cable.

•  If necessary, when bending the cable, please observe the manufacturer’s recommendations. Failure to do so could cause a communication failure.

•  Do not strip away the cable insulation any more than is necessary.

•  Perform termination in accordance with TIA/EIA-568A or 568B.

•  Before connecting the cable, be sure to verify conduction using a LAN checker or similar tool.

•  A RJ45 covered connector cannot be connected to the LAN ports of the master stations or the door stations. Use cables without covers on the connectors.

•  Be careful not to pull on the cable or subject it to excessive stress.

 

Precautions regarding low-voltage line

•  Use PE (polyethylene)-insulated PVC jacketed cable. Parallel or jacketed conductors, mid-capacitance, non-shielded cable is recommended.

•  Never use twisted-pair cable or coaxial cable.

•  2Pr quad V twisted pair cables cannot be used. 

Coaxial cable

Parallel cable

 

Connection and disconnection of low-voltage lines

•  Insert the line into the quick connection terminal.

•  If the line does not go in easily, push the low-voltage line into the terminal while pressing down the detachment button.

•  When removing a low-voltage line, pull on the line while pressing down the detachment button.

Detachment

button

Recommended

diameter of wire

ø0.8

8mm (5/16")

* The shape varies depending on a model.

 

When connecting low-voltage lines, perform the connection using either the crimp sleeve 

method or soldering, then insulate the connection with electrical tape.

Crimp terminal

Solid

wire

Stranded

wire

Solid

wire

Stranded

wire

Electrical tape

Soldering

Electrical tape

Line up the solid wire 

and stranded wire and 

crimp them together.

1

.

Overlap the tape by at 

least a half width and 

wrap the connection at 

least twice.

2

.

Twist the stranded 

wire around the solid 

wire at least 3 times.

1

.

After bending down the 

point, perform soldering, 

with care that no wires 

protrude from the 

soldering.

2

.

Overlap the tape by at 

least a half width and 

wrap the connection 

at least twice.

3

.

Crimp sleeve method

Soldering method

•  If the connector-attached lead wire is too short, extend the lead with an intermediate connection.

•  As the connector has polarity, perform the connection correctly. If the polarity is incorrect, the device will not operate.

•  When using the crimp sleeve method, if the end of the connector-attached lead wire has been soldered, first cut off the soldered part and then perform crimp.

• 

After completing connection of wires, check that there are no breaks or inadequate connections. When connecting low-voltage lines in particular, 

perform the connection using either soldering or the crimp sleeve method and then insulate the connection with electrical tape. For optimal 

performance, keep the number of wiring connections to a minimum.

Simply twisting low-voltage lines together will create poor contact or will lead to oxidization of the surface of the low-voltage lines over long-term use, causing poor 

contact and resulting in the device malfunctioning or failure.

Wiring Connection

Soldering method

Crimp sleeve 

method

Issue Date: Oct. 2018  FK2461  B  P1018 MQ 60409

How to Install

•  Insulate and secure unused low-voltage lines and the connector-attached lead wire.

100m (330')

LAN/PoE*

Cat-5e/6 straight

Paging input

3

PoE Switch

B+

B-

IX-MV7-*

3.5 mm 4-conductor stereo

mini jack

3.5 mm 4-conductor stereo

mini plug(1.8m (6'))

Contact input 1

 

1

Contact input 2

 

1

Contact input 3

 

1

Contact input 4

 

1

External speaker 

output 

4

Relay output 1

2

NO1

PE0.65 - 1.2(17 - 22AWG)-2C

PE0.65 - 1.2(17 - 22AWG)-2C

PE0.65 - 1.2(17 - 22AWG)-2C

PE0.65 - 1.2(17 - 22AWG)-2C

PE0.65 - 1.2(17 - 22AWG)-2C

Polarized

Voice input/output 

(CTIA standard compatible)

S1

S1E
S2

S2E
S3

S3E
S4

S4E
SP

SP

COM1

NC1

Relay output 2

2

NO2

COM2

NC2

*IEEE802.3 af

PE0.8(20AWG)-2C

PE0.8(20AWG)-2C

PE0.65 - 1.2(17 - 22AWG)-2C

Brown

Red

Orange

Yellow

Green
Blue

Purple

Gray

White
Black

15m (49')

Master Stations

2m (7')

1 Contact Input Specifications

Input method

Programmable dry contact (N/O or N/C)

Level detection method

Detection time

100 msec or more

Contact resistance

Make: 700 Ω or less

Break: 3 kΩ or more

Terminal short-circuit current

10 mA or less

Voltage between terminals

5.5 VDC or less (between open terminals)

2 Relay Output Specifications

Output method

Form C dry contact (N/O or N/C)

Contact rating

24 VAC, 1A (resistive load)

24 VDC, 1A (resistive load)

Minimum overload (AC/DC): 100mV, 0.1mA

3 Paging Audio Input Specifications

Input impedance

600 Ω

Input audio level

50 mVrms

4 External Speaker Output Specifications

Output impedance

8 Ω

Maximum output power

0.5 w

3