background image

Pg. 2

IS-SS-HID-I Instr.

0311JD

Aiphone Corporation

1700 130th AVE NE

Bellevue, WA 98005

(425) 455-0510 

Fax: (425) 455-0071

WIRING DIAGRAM:

IS-SS-HID-I

IS-CCU

IS-MV

Wiegand Wire 

 

Color

+ DC (10-16V) 

 

Red

Ground   

 

Black

Data0 

 

 

Green

Data1 

 

 

White

Shield Ground 

 

Drain

Green LED 

 

Orange

Red LED   

 

Brown

Beeper   

 

Yellow

Hold 

 

 

Blue

--- 

 

 

Violet

Connect the reader to the host according to the 

wiring table below and the host installation guide.

IS-PU-UL

TESTING & OPERATION:

•  When power is applied to the iCLASS® reader, the LED will turn RED while the beeper beeps 

simultaneously 3 times (the last tone is a higher frequency).  The LED will then flash once after the 

last tone.  This indicates that the microcontroller is operating properly. 

•  Present an iCLASS ID card to the reader (hold card directly in front of reader).  The LED 

will momentarily turn green while the beeper beeps once, indicating that the card was read 

successfully.

SPECIFICATIONS:

CARD READER:

Reader type:   

R10 (Rev. C)

Power Source: 

10 ~ 16V DC

Current: 

 

80mA (Avg); 300mA (peak)

Transmit Freq.  

13.56 MHz

Terminations:   

Color-coded pre-wired pigtail

Wiring Distance: 

500’

Operating Temp: 

14° ~ 140°F / -10° ~ 60°C

Operating Humidity:  5-95% relative humidity

 

 

 

non-condensing

DOOR UNIT:

Terminations:   

RJ45 jack for audio/video

 

 

 

Screw terminals for door release

Operating Temp: 

14° ~ 140°F / -10° ~ 60°C

Wiring Distance: 

980’ with Cat5e/6 cable

Dimensions:   

12-3/8” H x 7” W

w/SBX-ISDVFP: 

12-13/16” H x 7-1/16” W x 2-13/16” D  

 

 

 

(top), 1-13/16” D (bottom)

FCC WARNING:

This device complies with Part 15 of the FCC rules.

Operation is subject to the following two conditions:

(1)  This device may not cause harmful interference.

(2)  This device must accept any interference that may cause undesired operation.

• 

For proper regulatory compliance, the drain wire should be disconnected at the power 

supply end of the cable.

• 

Changes or modifications not expressly approved by the party responsible for 

compliance could void the user’s authority to operate the equipment.

• 

The Reader is intended to be powered from a limited power source output of a 

previously certifed power supply

TOLL FREE TECHNICAL SUPPORT:

(800) 692-0200

E-MAIL: [email protected]

NO

COM

NC

To Strike

& Power

CAT-5e

CAT-5e

Отзывы: