Pg. 2
IS-SS-HID-I Instr.
0311JD
Aiphone Corporation
1700 130th AVE NE
Bellevue, WA 98005
(425) 455-0510
Fax: (425) 455-0071
WIRING DIAGRAM:
IS-SS-HID-I
IS-CCU
IS-MV
Wiegand Wire
Color
+ DC (10-16V)
Red
Ground
Black
Data0
Green
Data1
White
Shield Ground
Drain
Green LED
Orange
Red LED
Brown
Beeper
Yellow
Hold
Blue
---
Violet
Connect the reader to the host according to the
wiring table below and the host installation guide.
IS-PU-UL
TESTING & OPERATION:
• When power is applied to the iCLASS® reader, the LED will turn RED while the beeper beeps
simultaneously 3 times (the last tone is a higher frequency). The LED will then flash once after the
last tone. This indicates that the microcontroller is operating properly.
• Present an iCLASS ID card to the reader (hold card directly in front of reader). The LED
will momentarily turn green while the beeper beeps once, indicating that the card was read
successfully.
SPECIFICATIONS:
CARD READER:
Reader type:
R10 (Rev. C)
Power Source:
10 ~ 16V DC
Current:
80mA (Avg); 300mA (peak)
Transmit Freq.
13.56 MHz
Terminations:
Color-coded pre-wired pigtail
Wiring Distance:
500’
Operating Temp:
14° ~ 140°F / -10° ~ 60°C
Operating Humidity: 5-95% relative humidity
non-condensing
DOOR UNIT:
Terminations:
RJ45 jack for audio/video
Screw terminals for door release
Operating Temp:
14° ~ 140°F / -10° ~ 60°C
Wiring Distance:
980’ with Cat5e/6 cable
Dimensions:
12-3/8” H x 7” W
w/SBX-ISDVFP:
12-13/16” H x 7-1/16” W x 2-13/16” D
(top), 1-13/16” D (bottom)
FCC WARNING:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may cause undesired operation.
•
For proper regulatory compliance, the drain wire should be disconnected at the power
supply end of the cable.
•
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
•
The Reader is intended to be powered from a limited power source output of a
previously certifed power supply
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
E-MAIL: [email protected]
NO
COM
NC
To Strike
& Power
CAT-5e
CAT-5e