Aiphone IS-SS-CI Скачать руководство пользователя страница 2

Pg. 2

IS-SS-CI Instr.

0413JD

Aiphone Corporation

1700 130th AVE NE * Bellevue, WA 98005

Ph: (800) 692-0200 * Fax: (425) 455-0071

[email protected]

WIRING DIAGRAM:

IS-SS-CI

IS-CCU

IS-MV

IS-PU-UL

CAT-5e

CAT-5e

FCC WARNING:

This device complies with Part 15 of the FCC rules.

Operation is subject to the following two conditions:

(1)  This device may not cause harmful interference.

(2)  This device must accept any interference that may cause undesired operation.

• 

For proper regulatory compliance, the drain wire should be disconnected at the power 

supply end of the cable.

• 

Changes or modifications not expressly approved by the party responsible for 

compliance could void the user’s authority to operate the equipment.

TOLL FREE TECHNICAL SUPPORT:

(800) 692-0200

E-MAIL: [email protected]

SPECIFICATIONS:

Terminations:   

RJ45 jack for audio/video

 

 

 

Screw terminals for door release and relay outputs

Relay rating:   

24V AC/DC 0.5A on Door station, 24V AC/DC 1.0A on relay board

Camera Input:  

Analog NTSC 1Vpp

Operating Temp: 

14° ~ 140°F / -10° ~ 60°C

Wiring Distance: 

980’ with Cat5e/6 cable

Dimensions:   

11-3/4” H x 7” W

w/SBX-ISDVFRA: 

11-11/16” H x 7-1/16” W x 2-13/16” D (top), 1-13/16” D (bottom)

OFF ON

NO

NO

C

NC

C

NC

1234

OFF ON

NO

NO

C

NC

C

NC

1234

Board on back of unit

See wiring below

RELAY BOARD WIRING AND SETTINGS:

CCTV Input
CCTV Output

Relay 1 Output

N/O, COM, N/C

Relay 2 Output

N/O, COM, N/C

For door release

1.0 Amp contact

*75Ω termination 

for CCTV output

* Unit is shipped with the pin connector set to the ON 

position. Change pin connector to the OFF position to 

loop video from the CCTV output.

Configuration Switch 

See Settings to right

ON

1
2
3
4

Default Configuration when shipped

Optional Configurations

ON

1
2
3
4

Normal Call

Emergency Call

Talking

Door Release

Trigger Source RY1 Triggered?

RY1 Remains ON 

During Talking?

RY2 Triggered?

RY2 Remains ON 

During Talking?

RY2 Requires 

Reset?

YES

NO

N/A

YES

NO

N/A

N/A

NO

N/A

YES

YES
YES
YES

YES

YES

N/A
N/A

N/A

NO

NO

Contact Technical Support if additional switch configurations 

are required.  

Normal Call

Emergency Call

Talking

Door Release

Trigger Source RY1 Triggered?

RY1 Remains ON 

During Talking?

RY2 Triggered?

RY2 Remains ON 

During Talking?

RY2 Requires 

Reset?

YES

NO

N/A

YES
YES

YES

YES

**

NO

NO

NO

NO

NO

N/A

N/A
N/A
N/A

YES

YES

NO

NO

**Connected to door 

release output 

of door station 

when shipped

Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.  

Relay 2 triggers when the door release button of the master is pressed.  Use this configuration if you need a larger 

relay contact than the 0.5 Amp supplied from the door station.

Relay 1 triggers on normal call, emergency call, and communication.  Relay 1 remains on during communication.

Relay 2 triggers on communication and remains on during communication.

*

* Connect to the IS-CCU or IS-SCU and 

program as a video door station, even if no 

CCTV camera is connected. 

ON

1
2
3
4

Normal Call

Emergency Call

Talking

Door Release

Trigger Source RY1 Triggered?

RY1 Remains ON 

During Talking?

RY2 Triggered?

RY2 Remains ON 

During Talking?

RY2 Requires 

Reset?

YES

NO

N/A

YES

NO

N/A

N/A

NO

N/A

YES

YES
YES
YES

YES

YES

N/A

N/A
N/A

NO
NO

***Option Input

Any N/O dry contact 

can be used.

*** Relay 1 triggers on normal call and communication.  Relay 1 remains on during communication. Relay 2 triggers 

when option input is triggered and remains on during communication.

If using this configuration Relay 2 can not be used for door release.  You must wire directly from the door station 

relay output for door release and disconnect the Red/Bown wires that are currently wired to the door station relay.

4-pin connector