Aiphone IS-SS-2RA Скачать руководство пользователя страница 2

Pg. 2

IS-SS-2RA Instr.

0413JD

Aiphone Corporation

1700 130th AVE NE * Bellevue, WA 98005

Ph: (800) 692-0200 * Fax: (425) 455-0071

tech@aiphone.com

WIRING DIAGRAM:

IS-SS-2RA

IS-CCU

IS-MV

IS-PU-UL

N/O Dry Contact 

0.5 Amp

CAT-5e

CAT-5e

NO

COM

NC

FCC WARNING:

This device complies with Part 15 of the FCC rules.

Operation is subject to the following two conditions:

(1)  This device may not cause harmful interference.

(2)  This device must accept any interference that may cause undesired operation.

• 

For proper regulatory compliance, the drain wire should be disconnected at the power 

supply end of the cable.

• 

Changes or modifications not expressly approved by the party responsible for 

compliance could void the user’s authority to operate the equipment.

TOLL FREE TECHNICAL SUPPORT:

(800) 692-0200

E-MAIL: tech@aiphone.com

SPECIFICATIONS:

Terminations:   

RJ45 jack for audio/video

 

 

 

Screw terminals for door release and relay outputs

Relay rating:   

24V AC/DC 0.5A on Door station, 24V AC/DC 1.0A on relay board

Camera Input:  

Analog NTSC 1Vpp

Operating Temp: 

14° ~ 140°F / -10° ~ 60°C

Wiring Distance: 

980’ with Cat5e/6 cable

Dimensions:   

11-3/4” H x 7” W 

w/SBX-ISDVFRA: 

11-11/16” H x 7-1/16” W x 2-13/16” D (top), 1-13/16” D (bottom)

OFF ON

NO

NO

C

NC

C

NC

1234

OFF ON

NO

NO

C

NC

C

NC

1234

Board on back of unit

See wiring below

RELAY BOARD WIRING AND SETTINGS:

CCTV Input
CCTV Output

Relay 1 Output

N/O, COM, N/C

Relay 2 Output

N/O, COM, N/C

**Relay 2 External Reset

Connect to N/O dry switch

*75Ω termination 

for CCTV output

* Unit is shipped with the pin connector set to the ON 

position. Change pin connector to the OFF position to 

loop the video signal from the CCTV output.

Configuration Switch 

See Settings to right

ON

1
2
3
4

Default Configuration when shipped

Optional Configuration

Normal Call
Emergency Call
Talking
Door Release

Trigger Source RY1 Triggered?

RY1 Remains ON 

During Talking?

RY2 Triggered?

RY2 Remains ON 

During Talking?

RY2 Requires 

Reset?

YES

NO

N/A

YES
YES

YES

YES

YES

NO

NO

NO
NO

N/A

N/A
N/A

N/A

N/A
N/A

YES

YES

ON

1
2
3
4

Contact Technical Support if additional switch configurations 

are required.  

* Connect to the IS-CCU or IS-SCU and program 

as a video door station, even if no CCTV camera 

is connected. If a CCTV camera is not connected, 

the video screen on the IS-MV will illuminate during 

communication with station. This is not a malfunction. 

Aiphone recommends the IS-SS-2RA-R station be 

used if no CCTV camera input is required.

*

Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.  

Relay 2 triggers on emergency call and remains on during communication.

Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.  

Relay 2 triggers on an emergency call and remains on during communication.  Relay 2 requires reset.

Normal Call
Emergency Call
Talking
Door Release

Trigger Source RY1 Triggered?

RY1 Remains ON 

During Talking?

RY2 Triggered?

RY2 Remains ON 

During Talking?

RY2 Requires 

Reset?

YES

NO

N/A

YES

NO

N/A

N/A

N/A

YES

YES
YES
YES

YES

YES

N/A

N/A
N/A

NO
NO

YES

**

4-pin connector

2-pin connector

Отзывы: