![Aiphone IS-IPRY8 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/aiphone/is-ipry8/is-ipry8_programming-manual_2872257008.webp)
IS-IPRY8 Wiring
8 | IS-IPRY8 Programming Manual
Aiphone Corporation
1700 130th Ave. NE Bellevue, WA 98005
Ph: (800) 692-0200 Fax: (425) 455-0071
www.aiphone.com [email protected]
IS-IPRY8 Dimensions
4-1/8”
3-5/16”
Mounting:
The IS-IPRY8 adaptor can mount to an Aiphone
W-DIN11 mounting rail (sold separately).
Depth:
1-1/4”
Door release:
External signaling:
Inputs:
Connect a normally open (N/O) button across any
input and ground.
Power:
Use a 9-30V DC (300mA @ 12VDC) power supply to
power the IS-IPRY8 adaptor. Use the Aiphone
PS-1225UL power supply (sold separately).
R1
NO
R3
NO
PT
Door
Strike
Bell
= Power Transformer (use proper power for the strike, mag lock, or external signaling device being used).
PS12
PT
PT
R2
NO
R4
NO
R1
NO
R3
NO
R2
NO
R4
NO
+
-
+
-
I1
I2
G
G
I3
I4
Input 1
Input 2
Input 3
Input 4
Ground
{
{
{
{
{
Relay 1
Relay 2
Relay 3
Relay 4
{
{
{
{
Relay 1
Relay 2
Relay 3
Relay 4
{
Power
Relay contact rating: 30V DC, 0.5A.
FCC WARNING:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may cause undesired operation.
•
For proper regulatory compliance, the drain wire should be disconnected at the power supply end of the cable.
•
Changes or modifi cations not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.