Страница 2: ...assurance doubly sure on the contents of this manual However if you find something questionable incorrect or omitted please contact the shop of purchase 4 Please note that AVAL DATA assumes no respon...

Страница 3: ...ntially hazardous situation that can result in minor moderate injury or property damage if you do not follow instructions Indicates a potentially hazardous situation that can result in electric shock...

Страница 4: ...Pull out the plug of power cord from AC outlet before installing removing peripheral device Installing removing peripheral device with power cord connected to AC outlet can cause electric shock Conne...

Страница 5: ...ird party 6 1 3 Disposal Method of the Product 6 Chapter2 General Description 7 2 1 Product Summary 7 2 2 Features 7 2 3 Specifications 8 2 4 Block Diagram 9 2 5 Case outline view 10 2 6 Connector pin...

Страница 6: ...AOC 162 User s Manual OM120000036A 4 3 Image capture limit 22 4 4 Power over Camera Link PoCL 22 Revision History 23 Inquiry 24...

Страница 7: ...product in a place exposed to direct sunlight or a place close to fire or heaters such as stoves Otherwise it can cause failure or deformation Do not use or store the product in a dusty place Do not...

Страница 8: ...heated to a high temperature please handle it with care Refer to the manual for the use of the system 1 2 After Sales Service 1 2 1 User s registration User s registration is required to use the afte...

Страница 9: ...line below Technical support Line E mail support avaldata co jp 1 2 3 User s manual A printed manual is not included with the shipment The manual is provided for download on the website It is based on...

Страница 10: ...rial number of the product is printed on the label on the main unit case and substrate the warranty certificate the box given each Location of the serial number label of the product is shown below ser...

Страница 11: ...ore connect us Check the followings in advance when consulting with us for the failure or abnormality of the product A Check the following in advance when consulting with us for the failure or abnorma...

Страница 12: ...each software shall be satisfied The software not permitted for its transfer and alienation shall be deleted before transfer B User to whom the product is transferred Be sure to inform us of the items...

Страница 13: ...mage data transmission trigger control and serial communication through an optical cable It can perform data transfer by 6 25Gbps communication speed that is equivalent to Camera Link Using optical tr...

Страница 14: ...r Core diameter 50 m 62 5 m Clad diameter 125 m The maximum distance changes with cable specification Communications protocol Opt C Link original protocol Power Over PoCL Specification SafePower not c...

Страница 15: ...M120000036A 2 4 Block Diagram Block Diagram of this product SDR 26pin SDR 26pin FPGA Arria GX EP2AGX45 CU17I3N CameraLink Receiver Opt Module Opt Module CameraLink Receiver DC 12V External trigger Fig...

Страница 16: ...A 2 5 Case outline view Case outline view of this product is shown below 10 Ch1 Ch2 HDR EC26LFDT1 SLD HONDA TSUSHIN KOGYO SFP connector AFBR 57D7AMZ Ch2 Ch1 HR10A 10R 12S HIROSE ELECTRIC AVAGO Technol...

Страница 17: ...hown below 2 6 1 Optical Connector OPT OUT 1 OPT OUT 2 This is an optical connector for connecting between the equipment of Opt C Link Connector form is SFP Manufacture AVAGO Technologies Model AFBR 5...

Страница 18: ...s Manual OM120000036A 2 6 2 Camera Link Connector CL IN1 CL IN2 This is a SDR connector corresponding to Camera Link Manufacture HONDA TSUSHIN KOGYO Model HDR EC26LFDT1 SLDP Figure2 6 2 Camera Link C...

Страница 19: ...SerTFG 19 SerTFG 7 SerTC 20 SerTC 8 X3 21 X3 9 XCLK 22 XCLK 10 X2 23 X2 11 X1 24 X1 12 X0 25 X0 13 GND 26 NC 12V PoCL Table2 6 2_2 CL IN 2 PinAssign Pin Signal Pin Signal 1 NC 12V PoCL 14 GND 2 CC4 1...

Страница 20: ...nnector Manufacture HIROSE ELECTRIC Model HR10A 10R 12S Figure2 6 3 PowerConnector Table2 6 3 PowerConnector PinAssign PinNumber Name 1 GND 2 Power Input DC 12V 3 NC 4 NC 5 NC 6 External trigger ch1 R...

Страница 21: ...ches correctly 3 1 1 CH1_PoCL CH2_PoCL Setup CH1_PoCL and CH2_PoCL respectively are the jumpers for PoCL setup of CH1 and CH2 PoCL function can be used by making 1 2pin Two pins above Fig 3 1 1 short...

Страница 22: ...ly the cover of a case separates change a jumper setup d Attach six M2 screws red arrow to become as before Open a cover only when you carry out PoCL setup Attachment of a case a Place this product on...

Страница 23: ...AOC 162 User s Manual OM120000036A 17 Figure 3 1 2_2 mounting dimension...

Страница 24: ...e optical cable is a lock mechanism Figure 3 1 3 connection of the optical cable The optical cable for connecting this product and frame grabber should meet the following specification Table 3 1 3 Opt...

Страница 25: ...rew lock and fix after inserting a CameraLink cable Figure 3 1 4 connection of the CameraLink Cable screw lock The optical cable for connecting this product and Camera should meet the following specif...

Страница 26: ...onnection of the power supply cable Connection of the power supply cable of this product is shown below Insert it close with a snapping motion because the optical cable is a lock mechanism Figure 3 1...

Страница 27: ...etting a register on a frame grabber Refer to User s Manual of APX 3800 for the method of a register setup Frame grabber ignore CC signal during using external trigger and ignore external trigger duri...

Страница 28: ...he restriction of line size depends on tap number The maximum line size inputted is shown in Table 4 3 Table 4 3 line size limit Tap number Maximum line size pixel 1 5461 2 10922 Monochrome 16384 3 RG...

Страница 29: ...AOC 162 User s Manual OM120000036A 23 Revision History Version Revised Date Revised Contents 2012 11 16 First edition...

Страница 30: ...6 2012 first edition edit AVAL DATA CORPORATION publish AVAL DATA CORPORATION OM120000036A C 2012 AVALDATA CORPORATION Head Quarters Machida office Sales department 1 25 10 Asahimachi Machida shi Toky...