AIMS AIMS Power PWRI150024S Скачать руководство пользователя страница 3

4.  ASSEMBLE

1. Location

    First ensure that there is enough space to install the inverter, while the installation  

location must meet the following requirements:

(1) Dryness: Avoid dripping water or other liquids on the inverter.

(2) Coolness: The operating temperature for the product is 32-104

°F

, the preferable 

temperature is 50-77

°F

, the lower temperature is better within this range.

(3) Ventilation: There should be a certain distance between inverter and other objects, 

to avoid blocking the product's vents. Allow 2 inches from openings.

(4) Cleanness: Do not install the product around dusty, wood chips or other particles. 

When the cooling fan turns on, the particles will be sucked into the inverter , thus 

increasing internal temperature..

(5) When connecting inverters and batteries, it will produce arcs or sparks, so there 

should not be flammable objects around, such as gasoline, alcohol, etc.

2.

2) Rear panel:

3) Remote control box (not included)

Remote control interface

3. Mounting the remote control box (Optional equipment)

2.  Mounting instructions

     Mount on a solid platform because of the  heavy weight, such as floor, table or 

stable support. In order to avoid sliding off, the platform should bear the weight of the 

product, and it is better to fix the product with four screws.

3.

1)

 the remote is designed to be mounted on a dash or other surface where a hole  should 

    

be cut so that it sits flush.  This is not a requirement however just a  recommendation.   

2) 

The remote cable should be plugged into inverter and the remote before mounted. 

Note: 

Optional remote is not needed for inverter operation.  The main power switch will 

          

work  the power on / off

.

 

  

Содержание AIMS Power PWRI150024S

Страница 1: ...Model number PWRI150012S 12V PWRI150024S 24V PWRI150048S 48V WARNING Please read this manual in its entirety before using or connecting this inverter It includes important instructions and safety tips ...

Страница 2: ...tly and safely please install and use it in a proper way Please read the instruction carefully before installing and using the inverter Pay special attention to the WARNING and NOTICE statements in the manual 1 Read the manual before using and keep it for future reference 2 Don t put the inverter in direct sun light heating source damp environment 3 The housing of inverter will get hot when using ...

Страница 3: ...rnal temperature 5 When connecting inverters and batteries it will produce arcs or sparks so there should not be flammable objects around such as gasoline alcohol etc 2 2 Rear panel 3 Remote control box not included Remote control interface 3 Mounting the remote control box Optional equipment 2 Mounting instructions Mount on a solid platform because of the heavy weight such as floor table or stabl...

Страница 4: ...pacity of the battery may also influence the result See the specification of the battery manufacturer for more detailed information 7 Connection 1 Grounding The power inverter has a terminal on the rear panel marked Grounding or This is used to connect the chassis of the power inverter to ground The ground terminal has already been connected to the ground wire of the AC output receptacle through t...

Страница 5: ...inse with cold water and go to hospital 3 Do not put any combustible materials in the location of installation for it will result in a fire hazard 4 Keep good ventilation The battery may produce a little flammable gas when used so keep away from the inverter and it is better to install them in a different space 5 Tighten all DC connections or it will result in the over reduction of the voltage or ...

Страница 6: ...en the input DC voltage is lower than 9 8V 19 6V 39 2V the buzzer will whistle intermittently to remind that the inverter will go into the under voltage protection Pay attention to save the data if you are using computer 2 Under voltage protection The inverter will automatically shut down when the input DC voltage is lower than 9 5V 19V 38V The buzzer will whistle continuously and the green light ...

Отзывы: