TROUBLESHOOTING TIPS
Fault / Display
Cause
Solutions
No output voltage, buzzer sounds
continuously
Low input DC voltage
Recharge or replace the battery
Do not use it when the battery is charging.
Check the rated voltage of the battery and
make sure it is in within the range of the input
voltage.
High input DC voltage
Overload
Reduce the load.
Over temperature
Cut off the load and let cool for 10 to 30
minutes. Restart it after it returns to normal
temperature
.
The load is too large, reduce
the total load to the range of rated power.
Avoid blocking the vent and improve the
ventilation condition
.
Reduce the ambient
temperature
.
No output voltage
The switch is off
Turn on the power switch.
Poor cable connection
Check the cables and make sure they are tightly
connected
and in good condition
.
Incorrect output voltage
RMS Multimeter measurement error
Use a true RMS multimeter to measure
,
such
as
model FLUKE 177/179.
The
battery
power
of
RMS
Multimeter is low.
Try to maintain the input voltage in the range
of rated power. The input voltage may be too
high or too low.
Change the battery of the multimeter then test
again
.
Cannot power the load
Load is too large
,
or the actual
power of the appliance
exceeds nominal power
.
Reduce the load
,
then turn on the
appliance first
,
then turn on the inverter.
The starting power is larger than
rated power (such as motor).
The internal inverter
soft-start circuit will buffer
starting the appliance.
8
Содержание PWRI60012120S
Страница 9: ...SPECIFICATIONS 9...