Page
37
of
92
▪
1: PSet
•
PSet (
‘1’ –
‘9’) for PSets 1
-
9, (‘A’ –
‘Z’) for PSets 10
-35
▪
CR: Carriage return control character
▪
LF: Line feed control character
▪
NULL*: Null control character (*if option is selected)
•
UEC Serial Modified Format (matches some Gen4 earlier versions):
o
# P 1 BB TTT.T
AAAA
PPPP 0000 J CR NULL*
▪
#: Message Start
▪
P: PSet
•
PSet (
‘1’ –
‘9’) for PSets 1
-
9, (‘A’ –
‘Z’) for PSets 10
-35
▪
1: Spindle Number (Always 1)
▪
BB: Job Bolt Count
•
Total number of accepts during the Job
▪
TTT.T: Torque Result
•
Units selected in the PSet
▪
AAAA
: Angle Result
•
Degrees
▪
PPPP: Pulse Count
▪
0000
▪
J: Judgment
•
‘@’ = Overall Pass, ‘H’ = Low Torque, ‘I’ = High Torque, ‘J’ = Low
Angle, ‘K = High Angle, ‘G’ = Fault During
Fastening
▪
CR: Carriage return control character
▪
NULL*: Null control character (*if option is selected)
•
Profibus Output Format:
o
%CAN 1 O P HHHHH LLLLL TTTTT
P HHHHH LLLLL AAAAA
NAC% CR LF NULL*
▪
%CAN: Message Start
▪
1: PSet
•
PSet (
‘1’ –
‘9’) for PSets 1
-9,
(‘A’ –
‘Z’) for PSets 10
-35
▪
O: Overall Pass/Fail
•
‘P’ = Pass, ‘F’ = Fail
▪
P: Torque Pass/Fail
•
‘P’ = Pass, ‘F’ = Fail
▪
HHHHH: Torque High Limit
•
Units selected in the PSet X10
▪
LLLLL: Torque Low Limit
•
Units selected in the PSet X10
▪
TTTTT: Torque Result