background image

OPERATIONS

Tool Body

Start Lever

Cable 

Connection

3

Multi Function 

Button

1. Connect tool cable to the iEC controller and the tool: 

The tool cable has curved alignment tabs and slots 
built into the connectors at each end to ensure proper 

 

alignment and connection with the tool and controller.

Make sure that power is not turned on at the controller 
before making any connections.

 Align the female connec-

tor on the cable with the male connector on the tool and insert 
the cable onto the tool, then slide the connector nut onto the 
threads on the cable and turn clockwise until hand-tight.

Align the male connector tab on the other end of the tool 
cable with the female slot on the controller and insert the 
cable into the connector, then slide the metal outer cover 
onto the connection threads on the controller and turn clock-
wise until hand-tight.

2. Multifunction Button Operation: 

The tool will flash all LED lights three times when power is 
first turned on at the controller. After the controller finishes 
initializing and displays a target toque value, the multifunction 
button (MFB) is used to toggle the tool from clockwise mode 
(FWD) to counter-clockwise operation mode (REV). The MFB 
is the small button opposite the trigger.  

The tool will initially start in clockwise mode and will have no 
LED lights turned on. If the trigger is pressed, the tool will 
turn on the blue LED meaning the tightening operation is 

underway. Pressing the MFB will cause the tool to flash yel-
low and red LED lights.  Pressing the MFB again will switch 
the tool back FWD mode and will indicate this with no LED 
lights turned on.

3. Start Lever Operation:

To start the tool, depress the start lever. Blue LED lights will 
be displayed while tightening a bolt. The tool will stop auto-
matically when it senses its target torque value or if no torque 
is sensed in a specified time period. After a cycle is complete, 
the tool will display green LED lights for a success, or red 
LED lights for failure to reach torque/angle.

A complete tool system consists of the following items:

Controller

Power Cord

Tool

Tool Cable

Light Ring Light Assignment

The Buzzer and Multi-Function Button are programmable in the 
DSP Menu of ToolWare.

Light Color

Meaning

Green Solid

OK

Red Flashing

Torque Low

Red Solid

Torque High

Yellow Flashing Angle Low
Yellow Solid

Angle High

Blue Solid

Tool In-Cycle/Tool Armed

Blue Flashing

P-Set Change thru MFB

All On Flashing

Tool in Disassembly

Buzzer

Bad Assembly/Tool in Disassembly/Power Up

Содержание AcraDyne Gen III 2000 Series

Страница 1: ...PO Box 16460 Portland OR 97292 0460 800 852 1368 Fax 800 582 9015 www aimco global com AcraDyne Gen III 2000 Series Tubenut runners Operations Manual ...

Страница 2: ... such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries If the maximum duty cycle of the attached tool is exceeded or the tool temperature exceeds 50 C then the operator should wear protective hand wear gloves c Avoid accidental starting Ensure the switch is in the off position before plugging in Carrying power tools wit...

Страница 3: ...counter clockwise operation mode REV The MFB is the small button opposite the trigger The tool will initially start in clockwise mode and will have no LED lights turned on If the trigger is pressed the tool will turn on the blue LED meaning the tightening operation is underway Pressing the MFB will cause the tool to flash yel low and red LED lights Pressing the MFB again will switch the tool back ...

Страница 4: ... X X 1 25273 SHIM 010 16 X X X X 1 25102 Screw BHC4 40X 188 STEEL BLACK OXIDE 17 X X X X 1 25402 T I D BOARD ASM GEN III 18 X X X X 2 24934 FLAT HEAD CAP SCREW 19 X X X X 1 25071 SPRING LEVER 20 X X X X 1 25074 LEVER ASSEMBLY 21 X X X X 2 20061 SCREW LEVER 22 X X X X 1 25072 O RING LED LIGHT RING COVER 23 X X X X 1 20534 3000 SERIAL MODEL LABEL 24 X X X X 1 25058 LIGHT RING COVER LED 25 X X X X 1 ...

Страница 5: ...of 120 RMS or 320 Volts Pulse DC Controller Supply Voltage of 230 RMS Duty Cycle The Nutrunner tools are intended for intermittent operation with recommended maximum duty cycles not to exceed 33 Note actual maximum duty cycles are dependant upon several factors including Ambient Temperature Tool selection Joint conditions fastening parameter programming anddifferent applications and strategies For...

Страница 6: ...etting this value too high can cause the socket to snap back to the home stop too quickly and potentially damage the tool Units lbf in approximation TID memory location 54 Typical Procedure for Setting the Tool s Tube Nut Home TID Parameters Set the Hold at Home Torque 0 Set the Home Detection Torque 1 Free run the tool and watch the homing routine while making the adjustments below Gradually incr...

Страница 7: ...Decreasing this can reduce the impact force when hitting the home stop Attention Care must be taken increasing the speed above the default value Too high of a value can greatly in crease how hard the output will hit the home stop and potentially damage the tool Units RPM of the tool output socket in the homing direction Default value 100 RPM Range 1 to 200 RPM Tube Nut Homing Acceleration Rate at ...

Страница 8: ...reliably detect an obstruction GEN III Controller Parameters Affecting Tube Nut Pinch Detection Controller parameters for soft start operation can be viewed and modified from the Controller Edit Controller Parameter Soft Start in ToolWare Soft Start Dwell Speed The Soft Start Dwell Speed is used during the check for obstructions Decreasing this can reduce the impact force when hitting an obstructi...

Страница 9: ...10 Tube Nut Homing Start Input Logic Selection The controller parameters for tube operation can be viewed and modified from the Controller Edit Controller Parameter Tube Nut screen in ToolWare Tube nut Home Strategy Lever action required to start the home sequence Options Home on release and repress of the lever default Home on release of the lever GEN IV Controller Parameters Affecting Tube Nut P...

Страница 10: ...NOTES 10 ...

Страница 11: ...NOTES 11 ...

Страница 12: ...MEXICO SA DE CV 10000 SE PINE STREET AVE CRISTOBAL COLON 14529 PORTLAND OREGON 97216 CHIHUAHUA CHIHUAHUA 31125 PHONE 503 254 6600 MEXICO TOLL FREE 1 800 852 1368 PHONE 01 614 380 1010 FAX 01 614 380 1019 LIT MAN164 REV 07 2020 PRINTED IN USA 2020 AIMCO ...

Отзывы: