CHAPTER 7
40
41
SOLO 2 DL
7.2.3 LCU-One CAN setting
Solo 2 DL can be connected to AiM LCU One CAN lambda controller plugging the 5
pins male Binder connector of LCU one in the female one bottom left of Solo 2 DL.
Once the expansion connected you need to set it:
n
enter “LCU-One CAN” tab
n
press “ADD” button; it switches to “Remove”
n
name your LCU One and fill in its serial number or press “Get SN from a connected
expansion” to receive the serial number from the connected LCU-One
n
select the multiplier to calculate AFR from lambda (in the example “14.57 Gasoline”)
or add a custom value pressing “Add Custom Value”
n
set the LCU One channels double clicking on each channel and setting the panel
that shows up
7.2.4 Parameters settings
Parameters page is divided in two parts.
n
on top
GPS Lap detection
parameters; mousing over the question marks a pop-up
message will explain you the working mode of:
n
hold lap time for: the time period for which lap time is shown on your
Solo 2 DL display
n
the track width: width that will be considered for any GPS point you set
n
bottom
Start data recording
conditions;
n
standard conditions (default setting) make Solo 2 DL start recording when
RPM is higher than 500 or speed is higher than 10 km/h
n
custom conditions: you can set two conditions and decide if making
Solo 2 DL start recording when only one of them is reached (“ANY”) or when
both are satisfied (“ALL”); pressing the button it sets the condition as shown
here below.
MANUALE SOLO 2DL .qxp_Layout 1 13/04/18 16:20 Pagina 43