12
7 – How to analyse LCU-One CAN data
Once the session is over and data have been downloaded from the AiM master logger, you can analyse them using Race Studio Analysis
software.
Running the software and opening the test you will see that
LCU-One CAN connection adds four channels to “Measures and
laps” bar (image on the right):
•
Lambda Val: shows Lambda value recorded during the
test
•
Lambda AFR: shows the stoichiometric value of the
fuel in use
•
Lambda_Temp: shows the working probe internal
temperature
•
Lambda Diagn: shows the probe status; values that
can be shown are:
0 = ok
1 = probe disconnected from controller and
circuit open
2 = 12V short circuit
3 = GND short circuit
Documents and tutorials relevant to LCU-One and Lambda
analysis are available at:
www.aim-sportline.com – Documentation area – On-Track
sessions.
Содержание LCU-ONE CAN
Страница 1: ...1 User Manual LCU One CAN for AiM loggers Release 1 00...
Страница 13: ...13 The image below shows a view of Race Studio Analysis 3 including Lambda figures...