3. Getting started
ANET1553-x
User’s Manual
27
3.9.1 Direct Coupling
Direct Coupling
connects the subsystem/terminal device
directly to the bus and can only be used in connections
under one foot in length.
Since a Direct Coupled stub provides only limited isolation
in the event of a device (subsystem or terminal) short,
Transformer Coupling is normally the recommended
method of connecting to the bus.
Figure 3.9-1 Pigtail Connector
AIM provided Pigtail Connector
A B
T
T
T
T
Terminators
A B
Bus A
Bus B
Stub Length One Foot Max
Figure 3.9-2 Direct Coupling