20
# Code
Function
00
Main Output always off at power-up (factory default)
01
Main Output status at power-up the same as at last power-down
02
Aux Output (T models only) always off at power up (factory default).
Set with control assigned to Output 1.
03
Aux Output (T models only) status at power up the same as at last power down.
Set with control assigned to Output 1.
20
Alarm output 'open' for main Output off, 'closed' for main Output on
21
Alarm output 'closed' when Aux Output is in Current Limit.
Set with control assigned to Output 1; applies to Output 1 alarm only.
22
Alarm output 'closed' when over-temperature trip occurs
23
Alarm output 'closed' when sense trip occurs
24
Alarm output 'closed' when over-current trip occurs
25
Alarm output 'closed' when over-voltage trip occurs
26
Alarm output 'closed' when any trip occurs (factory default)
30
Buzzer off
31
Buzzer on (factory default). A single beep indicates confirmation, a double beep
indicates a wrong entry.
33
Lock/Unlock settings. Note that the AUX output settings are locked with Output1.
40
Jog digit flashes, JOG indicator only flashes when jog is 'hidden'
41
JOG indicator always flashes, except when 'hidden' (factory default)
42
JOG indicator doesn't flash, except when 'hidden' (lazy flash)
91
Loads default calibration parameters. Refer to Service Guide
92
Shows firmware version number in the display
93
Sets these # settings to their factory default
94
Loads Factory Default settings (see below)
98
Clears all the output’s set-up memories. AUX output always cleared with O/P1.
In LINK mode, clears all memories in all modes (O/P1, O/P2, AUX & LINK).
99
Enter calibration mode. Refer to Service Guide.
Factory Default Settings
The ex-factory default settings (which will apply at first power-up) are as follows:
Range:
QL355: 35V/3A
QL564: 56V/2A
Voltage:
QL355: 1.000V
QL564: 1.000V
Current Limit:
QL355: 1.000A
QL564: 1.000A
OVP:
QL355: 40V
QL564: 60V
OCP:
QL355: 5.5A
QL564: 4.4A
Output:
Output off; local Sense
# Settings:
00
Main Output always off at power-up
02
Aux Output always off at power up (an Output 1 # function only).
26
Alarm output 'closed' when any trip condition occurs
31
Buzzer on
41
JOG indicator always flashes; 'lazy' flash when hidden